144 Circuits. Ib qho DFUN Multi-Loop Zog Meter System.
Nyob rau hauv ib tug qauv ib-meter-ib-circuit tsim, saib xyuas 144 hluav taws xob circuits yuav tsum tau mus txog rau 144 ib tug neeg meters. DFUN multi-loop zog meter sib sau ua ke tib qhov kev soj ntsuam mus rau hauv ib qho kev sib koom ua ke uas muaj xws li lub ntsiab tswj, ntsuas ntsuas ntsuas thiab tam sim no transformers.
DFPM206 txhawb nqa txog li 144 AC ceg-circuit saib xyuas raws, pab cov chaw zov me nyuam cov ntaub ntawv thiab lwm cov tshuab hluav taws xob muaj zog ua kom yooj yim rau kev tsim vaj huam sib luag, kev sib txuas lus, commissioning thiab ceg-theem zog tswj.

Dab tsi yog Multi-Loop Zog Meter?
Ib lub voj voog ntau lub zog ntsuas yog qhov ntsuas hluav taws xob hauv nruab nrab uas saib xyuas ntau yam khoom nkag thiab cov ceg hluav taws xob los ntawm ib tus tswj hwm. Tsis zoo li ib lub ntsuas pa uas ib txwm ua haujlwm rau ib lub voj voog, ntau lub voj voog sib txuas ua ke ntawm cov maub los, ntsuas cov qauv thiab cov ntsuas tam sim no los sau cov ntaub ntawv hluav taws xob hluav taws xob hauv ib qho kev sib koom ua ke.
DFUN muaj ntau lub voj voog ua qauv rau ob qho tib si AC thiab DC systems:
DFPM201 : mus txog 12 DC circuits
DFPM211 : mus txog 45 ib-theem ib zaug lossis 15-theem peb-theem AC circuits
DFPM206 : mus txog 144 AC ceg circuits
Qhov no modular mus kom ze yog qhov tseem ceeb tshwj xeeb tshaj yog thaum ib qhov project yuav tsum muaj kev kub ceev Circuit Court, txwv qhov chaw vaj huam sib luag, kev sib txuas lus hauv nruab nrab thiab cov ncauj lus kom ntxaws txog kev pom.
Tsob Ntoo Zog Meters vs. DFUN Multi-Loop Metering
Nyob rau hauv cov pa ib-meter-ib-circuit system, 144 soj ntsuam circuits yuav tsum tau mus txog 144 ib tug neeg meters. Lub DFUN multi-loop system siv lub hauv paus tswj hwm thiab cov ceg ntoo ua haujlwm los saib xyuas tib lub voj voog ntawm ib qho kev sib koom ua ke.
| Kev sib piv | Raws li cov meters | DFUN multi-loop system |
| Metering architecture | Ib tug standalone meter rau ib lub voj voog | Central controller nrog modular ntsuas units |
| units | ||
| 144-circuit project | Txog li 144 tus neeg meters | Ib qho DFPM206 system configuration |
| Vaj huam sib luag tsim | Rov ua dua 'meter' cutouts lossis DIN-rail khoom siv | Compact maub los thiab ntsuas modules |
| Kev xaim | Lub hwj chim thiab kev sib txuas lus txuas rov qab rau txhua lub 'meter' | Centralized kev sib txuas lus nrog modular expansion |
| Kev tswj cov ntaub ntawv | Kev ntsuas tau faib thoob plaws ntau yam khoom siv | Cov ntaub ntawv ceg tau teeb tsa hauv ib qho system |
| Kev nthuav dav | Ntxiv lwm lub meter tiav | Ntxiv tshaj 24- lossis 48-channel modules |
| Kev sib txuas lus | Nyob ntawm txhua tus 'meter' | Modbus RTU thiab Modbus TCP ntawm DFPM206 |
| Harmonic tsom xam | Model-nyob | Mus txog qhov kev txiav txim thib 63 ntawm DFPM206 |
| Kev tu | Ntau yam khoom siv hluav taws xob ywj pheej thiab chaw nyob | Coordinated system architecture |
| Kev sib txuas lus | Nyob ntawm txhua tus 'meter' | Modbus RTU thiab Modbus TCP ntawm DFPM206 |
| Harmonic tsom xam | Model-nyob | Mus txog qhov kev txiav txim thib 63 ntawm DFPM206 |
| Kev tu | Ntau yam khoom siv hluav taws xob ywj pheej thiab chaw nyob | Coordinated system architecture |
Cov ntsiab lus: DFUN tsis tsuas yog ua ib lub ntsuas me me xwb. Nws hloov ib qho kev faib ib-meter-ib-circuit architecture nrog ib tug modular multi-circuit saib xyuas.
Dab tsi DFUN Multi-Loop Zog Meter yog txoj cai rau koj qhov project?

DFPM201 Multi-Channel DC Zog Meter
DFPM201 yog tsim los rau -48 VDC daim ntawv thov xws li kev sib tham ntawm qhov chaw them nqi thiab DC tswj kev thauj khoom.
Cov ntsiab lus tseem ceeb
Txhawb txog li 12 ib-theem DC circuits
Voltage thiab tam sim no raug: Chav Kawm 0.5S
Lub zog raug: Chav Kawm 1.0
yog tsim los ntawm kev sib txuas lusKev sib txuas lus RS485
Modbus RTU raws tu qauv
Modular lub ntsiab tswj thiab ntsuas modules
Zoo tshaj plaws rau
Telecom sites
-48 VDC faib
➥ DC load xyuas
Ceg theem DC zog ntsuas

DFPM211 Multi-Channel AC Zog Meter
DFPM211 yog ib qho compact modular AC metering system rau telecom zog tswj, cov chaw zov me nyuam thiab lwm yam kev siv hluav taws xob ntau AC.
Cov ntsiab lus tseem ceeb
Txhawb txog li 45 ib-theem circuits
Txhawb txog li 15 lub voj voog peb theem
Voltage thiab tam sim no raug: Chav 0.5S
Lub zog raug: Chav 1.0
Kev sib txuas lus RS485 yog tsim los ntawm kev sib txuas lus
Modbus RTU raws tu qauv
Cov ntaub ntawv kev pab cuam installation
Txuag 50% qhov chaw teeb tsa
Txuag 50% lub sijhawm teeb tsa
Txuag 50% lub sijhawm debugging
Bes t suited rau
Medium-density AC faib
Telecom chaw
Kev tswj xyuas hluav taws xob ua lag luam
Data-center auxiliary distribution

DFPM206 Multi-Channel AC Zog Meter
DFPM206 yog tsim los rau cov chaw zov me nyuam cov ntaub ntawv thiab cov chav neeg rau zaub mov uas yuav tsum tau muaj cov ntaub ntawv ceev ceev kawg ntawm lub zog thiab kev saib xyuas lub zog ntawm lub sijhawm.
Cov ntsiab lus tseem ceeb
Ib lossis ob txoj kab tuaj
Ntau tshaj 144-channel ceg tso zis saib xyuas
24- lossis 48-channel ceg saib xyuas modules
Kev xaiv CT: 50 A lossis 100 A
Clamp-on lossis split-core CT xaiv
Xaiv qhov nruab nrab thiab qhov xau-tam sim no saib xyuas
Voltage thiab tam sim no harmonic tsom xam mus txog 63rd Order
Yim digital inputs thiab ob digital outputs
Ib qho RJ45 thiab ob qhov kev sib txuas lus RS485
Nws yog ib qho tseem ceeb uas yuav tsum tau ua los ntawm Modbus RTU thiab Modbus TCP
Optional touchscreen HMI
Ntau tshaj 5,000 cov ntaub ntawv tshwm sim
Keeb kwm query and fault diagnosis
DIN-rail installation
Kev ntsuas qhov tseeb
➥ Voltage thiab tam sim no: ± 0.5%
Lub zog thiab lub zog: ± 1%
Zaus: ± 0.02 Hz
Zoo tshaj plaws rau
Data Centers
Server chav
High-density branch circuit monitoring
Tau qhov tseem ceeb ntawm lub hwj chim faib vaj huam sib luag
Endpoint zog tswj
DFPM206 144-Circuit System ua haujlwm li cas?
DFPM206 system yog tsim nyob rau hauv plaub txheej txheej:
1. Ceg tam sim no transformers
Tam sim no transformers ntsuas tus kheej tawm circuits. DFPM206 txhawb nqa 50 A thiab 100 A ceg CT kev xaiv hauv clamp-on lossis split-core configurations.
2. Ceg saib xyuas modules
DFPM206 ceg units saib xyuas 24 lossis 48 ib-theem circuits. Ntau lub modules tuaj yeem ua ke los ntsuas qhov system mus rau qhov siab tshaj plaws ntawm 144 ceg raws.
3. Main tswj
DFPM206 lub ntsiab tswj xyuas ib lossis ob txoj kab tuaj, npaj cov ntaub ntawv ceg thiab muab kev sib txuas lus nrog cov kev soj ntsuam saum toj kawg nkaus.
4. Central saib xyuas platform
Tus maub los txuas rau lub zog saib xyuas, kev tswj xyuas cov ntaub ntawv hauv chaw, kev tswj vaj tsev lossis kev tswj hwm lub zog los ntawm Modbus TCP lossis Modbus RTU.
Qhov tshwm sim yog ib qho kev sib koom tes saib xyuas architecture los ntawm lub sensor tam sim no mus rau kev tswj hwm platform.

Data Centers
Monitor high-density branch circuits, incoming feeds and server-room power distribution. DFPM206 pab cov neeg ua haujlwm sib piv cov khoom thauj, txheeb xyuas cov kab hluav taws xob txawv txav thiab sib koom ua ke cov ntaub ntawv qib theem nrog lub hauv paus saib xyuas lub platform.
Telecom Sites
Siv DFPM201 rau -48 VDC loads lossis DFPM211 rau AC faib. Ob qho qauv txhawb kev ntsuas qhov nruab nrab ntawm ntau lub voj voog nyob rau hauv qhov chaw sib txuas lus hauv ib puag ncig.
Cov Khoom Siv Muaj
Centralize load thiab lub zog saib xyuas thoob plaws ntau lub zog hluav taws xob. Siv cov cuab yeej ntsuas ntsuas los txhawb kev npaj muaj peev xwm, kev saib xyuas thiab ntsuas hluav taws xob.
Cov tsev lag luam
Saib xyuas cov neeg xauj tsev, hauv pem teb, cov cuab yeej siv lossis cov chaw ua haujlwm yam tsis muaj kev txhim kho ib qho kev ntsuas tag nrho rau txhua qhov kev soj ntsuam xyuas.
Critical Power Systems
Taug qab cov khoom nkag thiab tawm hauv cov kab ke uas muaj lub sijhawm ua haujlwm, lub tswb pom kev pom thiab cov ntaub ntawv nkag mus rau hauv nruab nrab yog qhov tseem ceeb ntawm kev ua haujlwm.

FAQ
Q1: Dab tsi yog qhov txawv ntawm ib lub voj voog ntau lub zog ntsuas thiab lub ntsuas pa?
A: Ib lub zog ntsuas hluav taws xob ib txwm ntsuas ib lub voj voog. Lub tshuab ntsuas hluav taws xob ntau lub zog siv ib qho kev tswj hwm thiab ntsuas ntsuas ntsuas ntsuas los saib xyuas ntau yam khoom nkag thiab cov ceg txuas hauv ib qho kev sib koom ua ke.
Q2: Ib qho DFUN puas tuaj yeem saib xyuas 144 circuits?
Q3: Puas yog '144 circuits, ib qho system' txhais tau tias yog ib lub 'meter'?
Q4: Tus qauv DFUN twg txhawb nqa DC circuits?
Q5: Tus qauv DFUN twg txhawb nqa 45 AC circuits?
Q6: Cov kev sib txuas lus twg puas txhawb nqa DFPM206?
Q7: DFPM206 puas tuaj yeem soj ntsuam kev sib haum xeeb?
Q8: Puas yog DFPM206 haum rau cov chaw zov me nyuam?
Q9: Kuv yuav ua li cas thiaj li tau txais daim ntawv thov DFUN multi-loop meter?
Related Blogs
-
Internal resistance yog ib qho ntawm feem txhim khu kev qha thaum ntxov ntawm VRLA roj teeb kev noj qab haus huv, tab sis tsis muaj ib tug universal tooj uas qhia koj thaum twg los hloov lub roj teeb - kev nyeem ntawv tsuas yog txhais tau hais tias ib yam dab tsi tawm tsam lub xov tooj ntawm tes lub hauv paus. Kab lus no rhuav tshem txoj cai 50% - saum toj no-pib hloov txoj cai, 20-30% cell-to-cell deviation check rau pom ib lub lagging unit, thiab vim li cas ib tug tam sim ntawd dhia nyob rau hauv kuj tseem ceeb tshaj li tus nqi siab. Nws kuj tseem hais txog vim li cas qhov kev tiv thaiv ib leeg tsis txaus - ua ke nrog kev ntsuas hluav taws xob ntab, ntsuas qhov muaj peev xwm tawm, thiab kev tshuaj xyuas qhov muag - thiab yuav ua li cas DFUN kev sib xyaw roj teeb saib xyuas thiab lub peev xwm ntsuas lub platform automates qhov pib taug qab thoob plaws ib txoj hlua.Case Study -
Cov ntaub ntawv chaw yog ib qho tseem ceeb ntawm txhua qhov kev lag luam hauv ntiaj teb niaj hnub no cov ntaub ntawv-tsav. Muaj kev nce ntxiv hauv cov ntaub ntawv khaws cia thiab kev tswj hwm kev xav tau nyob rau xyoo kaum xyoo dhau los, ua rau muaj kev nce hauv cov chaw zov me nyuam cov ntaub ntawv, qhov ntsuas, thiab qhov nyuaj. Raws li qhov xwm txheej no, kev saib xyuas tej thaj chaw debNqe lus nqi -
Hauv cov chaw ua haujlwm tseem ceeb xws li tshav dav hlau, cov chaw khaws ntaub ntawv, thiab cov tsev kawm ntawv loj, kev cia siab rau lub zog yog qhov tseem ceeb. Kev tswj ntau txhiab lub roj teeb hauv UPS cov tshuab tau dhau los ua qhov nyuaj, thiab cov txheej txheem kev saib xyuas ib txwm tsis txaus.Case Study
Tau txais DFUN Multi-Loop Metering Proposal
Xa peb cov kev suav hauv Circuit Court, daim duab kab ib kab thiab kev sib txuas lus. Peb pab neeg yuav pom zoo kom tsim nyog DFUN maub los, ntsuas modules thiab tam sim no sensors.
Mob: + 15919182362
Email: info@dfuntech.com