og

Yakabatanidzwa Backup Power Monitoring Management Platform

DFCS4200 | Iyo Yehungwaru Platform yeYakazara Lifecycle Monitoring yeBattery uye Power Systems

Kumba DFUN Multi-Loop Energy Meter

144 Masenhu. Imwe DFUN Multi-Loop Energy Meter System.

Mune yakajairwa mita imwe-per-circuit dhizaini, kutarisa 144 matunhu emagetsi angada kusvika 144 yega mita. Iyo DFUN yakawanda-loop simba mita inosanganisa iyo imwechete yekutarisa chiyero mune imwe yakarongeka sisitimu ine mutongi mukuru, modular kuyerwa mayuniti uye azvino anoshandura.


Iyo DFPM206 inotsigira kusvika ku144 AC bazi-dunhu rekutarisa nzira, kubatsira nzvimbo dzedata uye mamwe-akakwirira-density magetsi masisitimu kurerutsa mapaneru dhizaini, kutaurirana, kutumwa uye bazi-level simba rekutonga.

Madimikira akakosha
Kusvika ku144 AC bazi-dunhu rekutarisa machanera
Modbus RTU uye Modbus TCP kutaurirana
Voltage uye ikozvino harmonic ongororo kusvika ku63rd kurongeka
Imwe kana maviri anouya-mutsetse wekutarisa sarudzo
Modular 24- kana 48-chanera mapazi mapazi
og

Chii chinonzi Multi-Loop Energy Meter?

Iyo yakawanda-loop simba mita ndiyo yepakati magetsi yekuyera sisitimu inotarisisa akawanda anouya uye ebazi maseketi kuburikidza nemutongi mumwe. Kusiyana nemamita akajairwa anowanzo shanda dunhu rimwe, iyo yakawanda-loop system inosanganisa controller, kuyerwa mamodules uye ikozvino sensors kuunganidza redunhu-level data yemagetsi mune imwe yakarongeka architecture.

DFUN inopa yakatsaurirwa akawanda-loop modhi kune ese AC uye DC masisitimu:

DFPM201: anosvika gumi nemaviri DC maseketi

DFPM211: inosvika makumi mana neshanu-chikamu chimwe kana gumi neshanu-chikamu chetatu AC maseketi

DFPM206: anosvika 144 AC mapazi maseketi


Iyi modular nzira inonyanya kukosha kana purojekiti ichida kukwirira kwedunhu, nzvimbo shoma yepaneru, kutaurirana kwepakati uye kuoneka kwakadzama kwebazi.

Sei Uchishandisa DFUN Multi-Loop Energy Meter?

Sarudza iyo DFUN yakawanda-loop simba mita kana akawanda maseketi emagetsi anofanirwa kutariswa mukati meakaganhurirwa mapaneru tsoka uye inotungamirwa kuburikidza neako imwe yekutaurirana.
Panzvimbo pekudzokorora mita yakazara, kuratidza, yekuwedzera simba rekubatanidza uye netiweki kero yedunhu rega rega, DFUN inoisa pakati kuyerwa nekutaurirana. Izvi zvinogadzira yekuchenesa sisitimu yekuvaka, inoderedza zvinodzokororwa zvikamu uye inoita kuti data ive nyore kubatanidza mumagetsi ekutarisa kana chikuva chekutonga chikuva.

1. Tsiva imwe-mita-per-circuit architecture

Nemamita akajairwa, bazi rega rega rinotariswa rinogona kuda mita yakaparadzana. Pamaseketi 144, izvo zvinogona kureva anosvika zana nemakumi mana nemana ega ega, wiring inodzokororwa uye nhamba huru yekutaurirana kero.
DFPM206 inotarisisa anosvika zana nemakumi mana nemana maseketi ebazi seimwe yakarongeka yakawanda-loop system. Iyo sisitimu ichiri kushandisa modular kuyerwa mayuniti uye azvino shanduri, asi inobvisa kukosha kwekuisa yakakwana yakamira mita yebazi rega rega.

2. Wedzera kutarisa density


High-density kugovera mapaneru anowanzo kuve neakawanda maseketi kupfuura akajairwa mamita marongero anogona kugarisa zvakanaka. DFUN inoparadzanisa mutongi kubva kumamodule ekuyera kwebazi, ichibvumira mamwe maseketi kuti atariswe pasina kuzadza pani nemamita ega ega kumeso.

3. Rerutsa kubatanidzwa kwehurongwa


DFPM206 inotsigira zvese Modbus RTU uye Modbus TCP. Zviyero zvebazi-dunhu zvinokwanisa kubatanidzwa mune imwe nzvimbo yekutarisa simba repakati panzvimbo yekutungamirirwa semuunganidzwa wakakura wemamita asingaenderane akamira.

4. Kuvandudza kuoneka kwebazi

Iyo DFPM206 sisitimu inogona kutarisa magetsi ma paramita pane anouya uye ebazi maseketi, anosanganisira:
Voltage
Current
Simba rinoshanda
Kushandiswa kwesimba
Power factor
Frequency
Mamiriro edunhu
Alamu uye chiitiko ruzivo
Izvi zvinoita kuti vashandi vaone mitoro isina kujairika, kuenzanisa kushanda kwebazi uye kuongorora kushandiswa kwesimba pane imwe nhanho inobatsira kupfuura mita imwe chete.

5. Tsigira simba-mhando yekuongorora


DFPM206 inopa voltage uye ikozvino harmonic ongororo kusvika ku63rd kurongeka. Izvi zvinobatsira mainjiniya uye zvikwata zvekushanda kuongorora kukanganiswa kwewaveform uye simba-mhando mamiriro munzvimbo dzakakosha dzekugovera-simba.

6. Deredza kuisa uye kutumira basa


Iyo DFUN Meter Catalog inonyora zvinotevera mabhenefiti eDFPM211 akawanda-channel AC simba mita:
50% shoma yekuisa nzvimbo
50% mashoma ekuisa maawa
50% shoma system debugging nguva
Huwandu uhu hunoshanda chaizvo kune iyo DFPM211 catalogue kumisikidzwa. Kuchengetedzwa chaiko kweprojekiti kunoenderana nehuwandu hwedunhu, dhizaini yepaneru, dhizaini yewaya uye mamiriro esaiti.

Traditional Energy Meters vs. DFUN Multi-Loop Metering

Mune yakajairwa imwe mita-per-circuit system, 144 inotariswa maseketi angangoda kusvika 144 yega mita. Iyo DFUN yakawanda-loop sisitimu inoshandisa yepakati controller uye modular bazi mayuniti kutarisa yakafanana dunhu chiyero kuburikidza nehumwe hwakarongwa dhizaini.

KuenzanisaMamita akajairikaDFUN multi-loop system
Metering architectureMeta imwe yakamira padunhuCentral controller ine modular kuyerwa zvikamu
units
144-dunhu chirongwaKusvikira 144 munhu mumwe mamitaImwe DFPM206 system kumisikidza
Panel designAkadzokororwa mita cutouts kana DIN-rail zvishandisoCompact controller uye kuyerwa modules
WiringSimba uye kutaurirana wiring inodzokororwa kune imwe neimwe mitaKukurukurirana kwepakati nekuwedzera kwe modular
Data managementZviyero zvakagoverwa pamidziyo yakawandaDavi rebazi rakarongwa mukati mehurongwa humwe
KuwedzeraWedzera imwe mita yakakwanaWedzera inoenderana 24- kana 48-chiteshi modules
CommunicationsZvinoenderana nemamita ega egaModbus RTU uye Modbus TCP paDFPM206
Harmonic kuongororaModel-inotsamiraKusvikira ku63rd odha paDFPM206
MaintenanceMazhinji akazvimirira mita zvishandiso nemakeroCoordinated system architecture
CommunicationsZvinoenderana nemamita ega egaModbus RTU uye Modbus TCP paDFPM206
Harmonic kuongororaModel-inotsamiraKusvikira ku63rd odha paDFPM206
MaintenanceMazhinji akazvimirira mita zvishandiso nemakeroCoordinated system architecture

Pfupiso: DFUN haingoite diki yakajairika mita. Iyo inotsiva yakagoverwa-meta-per-dunhu architecture ine modular yakawanda-yedunhu yekutarisa system.

Ndeipi DFUN Multi-Loop Energy Meter Yakakodzera Chirongwa Chako?

企业微信截图_ 17883429678 8

DFPM201 Multi-Channel DC Energy Meter

DFPM211 Debugging Vhidhiyo

DFPM211 Multi-Channel AC Energy Meter

DFPM211 ndeye compact modular AC metering system ye telecom simba manejimendi, nzvimbo dzedata uye mamwe akawanda-edunhu AC maapplication.


Madimikira akakosha

Inotsigira anosvika makumi mana neshanu-chikamu chimwe chete maseketi

Inotsigira anosvika gumi nemashanu-matatu-chikamu maseketi

Voltge uye ikozvino kurongeka: Kirasi 0.5S

Kurongeka kwesimba: Kirasi 1.0

RS485 kutaurirana

Modbus RTU protocol


Zvinyorwa zvekuisa mabhenefiti

Inochengetedza 50% yekuisa nzvimbo

Inochengetedza 50% maawa ekuisa

Inochengetedza 50% system debugging nguva


Bes t yakakodzera

 Medium-density AC kugovera

 Telecom zvivakwa

 Kutarisira simba rekutengeserana

 Data-center yekubatsira kugovera


dfpm206-mita

DFPM206 Multi-Channel AC Energy Meter

DFPM206 yakagadzirirwa nzvimbo dzedata uye makamuri evhavha ayo anoda yakakwira-density endpoint simba rekuunganidza data uye chaiyo-nguva simba-kugovera yekutarisa.


Madimikira akakosha

Mutsetse mumwe kana miviri inouya

Maximum 144-chiteshi chebazi chinobuda chekutarisa

24- kana 48-chiteshi chebazi chekutarisa modules

Bazi CT sarudzo: 50 A kana 100 A

Clamp-on kana split-core CT sarudzo

Inosarudzika kusarerekera uye kuvuza-ikozvino kutarisa

Voltage uye yazvino harmonic ongororo kusvika ku63rd kurongeka

Magetsi masere edhijitari uye maviri edhijitari akabuda

Imwe RJ45 uye maviri RS485 kutaurirana nzvimbo

Modbus RTU uye Modbus TCP

Optional touchscreen HMI

Marekodhi ezviitiko anodarika zviuru zvishanu

Mubvunzo wezvakaitika kare uye kuongororwa mhosva

DIN-njanji yekuisa


Kuyera kurongeka

Voltge uye zvazvino: ±0.5%

Simba nesimba: ±1%

Kakawanda: ±0.02 Hz


Yakanyatsokodzera

Data centers

Makamuri esevha

High-density bazi redunhu rekutarisa

Magetsi akakosha-kugovera magetsi

Endpoint energy management


Iyo DFPM206 144-Circuit System Inoshanda Sei?

Iyo DFPM206 sisitimu inovakwa muzvikamu zvina zvakabatanidzwa:

1. Bazi ikozvino transformers

Ma transformer azvino anoyera masekete ari kubuda ega. DFPM206 inotsigira 50 A uye zana A bazi CT sarudzo mune clamp-on kana kupatsanura-musimboti masisitimu.

2. Bazi monitoring modules

DFPM206 bazi mayuniti anotarisisa makumi maviri nemana kana makumi mana nemasere echikamu chimwe chete. Multiple modules inogona kusanganiswa kuyera sisitimu kusvika pakakwirira ye144 bazi nzira.

3. Mutongi mukuru

Iyo DFPM206 main controller inotarisisa mutsara mumwe kana maviri anouya, anoronga dhata rebazi uye inopa kutaurirana neyekumusoro yekutarisa chikuva.

4. Central monitoring platform

Iyo controller inobatanidza kune yekutarisa simba, data-center manejimendi manejimendi, manejimendi ekuvaka kana simba manejimendi chikuva kuburikidza neModbus TCP kana Modbus RTU.

Mhedzisiro yacho ndeye yakarongeka yekutarisa zvivakwa kubva kune yazvino sensor kuenda kune manejimendi chikuva.

Yakakosha Tekinoroji Yakanakira yeDFUN Multi-Loop Metering

Modular system architecture


Sarudza mutongi, nhamba yekuyera mamodules uye sensor kumisikidza zvinoenderana neiyo chaiyo yedunhu kuverenga. Izvi zvinodzivirira kumanikidza purojekiti yega yega mune imwechete yakagadziriswa mita

Centralized communications


Panzvimbo pekutonga gumi nemaviri kana mazana emamita akazvimirira kero, iyo DFUN yakawanda-loop sisitimu inoronga kuyerwa kwebazi kuburikidza neyakarongeka yekutaurirana chimiro.

High-density panel monitoring


DFPM206 inotsigira anosvika zana nemakumi mana nemana maseketi emapazi, zvichiita kuti ive yakakodzera kune gobvu-kugovera magetsi nharaunda uko akajairwa mamita anoshandisa nzvimbo yakawandisa.

AC uye DC chigadzirwa chekuvhara


Iyo DFUN yakawanda-loop mhuri inovhara -48 VDC telecom masisitimu, yepakati-density AC zvikumbiro uye yakakwirira-density AC bazi rekutarisa.

Flexible current sensing


Inowanikwa CT zvigadziriso zvinobvumira sisitimu kuti ienderane zvakasiyana zvinouya uye zvebazi-zvazvino zvinodiwa.

Real-time maaramu uye marekodhi echiitiko


DFPM206 inotsigira chaiyo-nguva aramu kuratidzwa, kutema chiitiko, nhoroondo data mibvunzo uye kutadza kuongororwa kuburikidza neyayo sarudzo yeHMI.

Applications

Telecom nzvimbo


Data Centers


Monitor high-density bazi circuits, mafeed anouya uye server-room power distribution. DFPM206 inobatsira vashandisi kuenzanisa mitoro, kuona matunhu asina kujairika uye kubatanidza bazi-level data nepakati pekutarisa chikuva.


Telecom Sites

Shandisa DFPM201 ye -48 VDC mitoro kana DFPM211 yekugovera AC. Mamodheru ese ari maviri anotsigira yepakati-yakawanda-yedunhu kuyerwa munzvimbo-yakamanikidzwa telecom nharaunda.

Industrial Facilities

Isa pakati mutoro uye simba rekutarisa pane akawanda-redunhu magetsi mapaneru. Shandisa zviyero zvebazi kutsigira kuronga kwemasimba, kuchengetedza uye kuongorora simba.

Zvivako zvekutengesa

Monitor maroja, pasi, mapoka emidziyo kana nzvimbo dzinoshanda pasina kuisa yakaparadzana yakazara mita kune yega yega inotariswa dunhu.

Critical Power Systems

Tevera masekete anouya uye anobuda mune masisitimu umo nguva, alarm kuoneka uye centralized data kuwana zviri pamberi pekushanda.

Maitiro ekusarudza Multi-Loop Energy Meter

Usati wasarudza modhi, simbisa iyo inotevera purojekiti ruzivo:


1.Is system AC kana DC?
2.Mangani emitsara anouya anofanira kutariswa?
3.Mangani echikamu chimwe chete kana matatu-chikamu matunhu ebazi anodiwa?
4.Ndeipi iyo inouya uye yebazi ikozvino mitsara?
5.Ndeipi kuyerwa kwechiyero kunodiwa?
6.Is harmonic analysis inodiwa here?
7.Is Modbus RTU, Modbus TCP kana zvose zvinodiwa?
8.Is a local touchscreen HMI inodiwa?
9.Is kwazvakarerekera kana kuvuza-ikozvino kutarisa kunodiwa?
10.Yakawanda sei DIN-njanji uye nzvimbo yepaneru inowanikwa?


DFUN inogona kushandisa ruzivo urwu kusarudza mutongi, mamodule ebazi, maCTs uye kugadziridzwa kwekutaurirana kweprojekiti.

FAQ

Q1: Ndeupi musiyano pakati pe-multi-loop simba mita uye yakajairika mita?

A: Meta yemagetsi yakajairika inowanzoyera dunhu rimwe. Iyo yakawanda-loop simba mita inoshandisa imwe controller uye modular kuyerwa mayunitsi kutarisa akawanda anouya uye ebazi maseketi mukati meimwe yakarongeka system.

Q2: Imwe DFUN system inogona kutarisa 144 maseketi?

Q3: Ko 'maseketi 144, one system' anoreva mita imwe chete yemuviri?

Q4: Ndeipi DFUN modhi inotsigira DC maseketi?

Q5: Ndeipi DFUN modhi inotsigira makumi mana neshanu AC maseketi?

Q6: Ndeapi maprotocol ekutaurirana anotsigirwa neDFPM206?

Q7: Ko DFPM206 inogona kuongorora harmonics?

Q8: Ko DFPM206 yakakodzera nzvimbo dzedata?

Q9: Ini ndinowana sei DFUN multi-loop mita chikumbiro?

Mhedziso


DFUN akawanda-loop simba metres inotsiva yakagoverwa-mita-per-dunhu dhizaini ine yepakati uye modular yekutarisa yekuvaka. DFPM201 inovhara anosvika gumi nemaviri DC maseketi, DFPM211 inovhara anosvika makumi mana neshanu-chikamu chimwe kana gumi neshanu-chikamu chetatu AC maseketi, uye DFPM206 zviyero kusvika 144 AC mapazi maseketi.


Kune nzvimbo dzedhata, nzvimbo dzenhare uye mamwe masisitimu emagetsi epamusoro, nzira iyi inorerutsa dhizaini yepaneru, inosimbisa kutaurirana uye inopa inonyanya kukosha yebazi-level data data.

Related Blogs

  • UPS Battery Internal Resistance: Unofanira Kuitsiva Rini?
    Kupikiswa kwemukati ndeimwe yeakavimbika ekutanga zviratidzo zveVRLA hutano hwebhatiri, asi hapana imwe nhamba yepasirese inokuudza nguva yekutsiva bhatiri - kuverenga kunongoreva chimwe chinhu chinopesana nehwaro hwesero. Ichi chinyorwa chinotyora iyo 50% -pamusoro-yekutanga-yekutsiva mutemo, iyo 20-30% sero-kune-sero kutsauka kwekuona yakarembera unit, uye nei kusvetuka nekukasira mukupikisa kuchikosha kupfuura kukosha kwepamusoro. Inovharawo kuti nei kuramba kwega kusina kukwana - kuibatanidza neyakayangarara magetsi cheki, kuyedzwa kwekuburitsa simba, uye ongororo yekuona - uye kuti DFUN yakabatanidzwa sei bhatiri yekutarisa uye yekuyedza chikuva inoitisa chikumbaridzo kuteedzera tambo yese.
    Nyaya Yokudzidza
  • Iyo Yakanakisa Battery Monitoring masisitimu eData Center
    Iyo data centre chinhu chakakosha chebhizinesi chero ripi zvaro munyika yanhasi inofambiswa nedata. Pakave nekuwedzera kwakakura kwekuchengetwa kwedata uye manejimendi zvinodiwa mukati memakore gumi apfuura, zvichikonzera kuwedzera kwenzvimbo yedata, chiyero, uye kuoma. Pasi pemamiriro ezvinhu aya, kure kutarisa solut
    Value Article
  • UPS Battery Management & Monitoring System yeAirports | Kuvimbisa Simba Rakavimbika kuSingapore Airport
    Munzvimbo dzakakosha dzemishini dzakadai senhandare dzendege, nzvimbo dzedata, uye makampasi makuru, kuvimbika kwesimba rekuchengetedza kwakakosha. Kutarisira zviuru zvemabhatiri muUPS masisitimu zvave kuwedzera kuoma, uye nzira dzechinyakare dzekugadzirisa hadzichakwane.
    Nyaya Yokudzidza

Tora DFUN Multi-Loop Metering Proposal

Titumirei nhamba yako yedunhu, dhayagiramu-mutsara mumwe uye zvinodiwa zvekutaurirana. Chikwata chedu chichakurudzira iyo yakakodzera DFUN controller, kuyerwa mamodule uye azvino sensors.

Mhomho:+86- 15919182362

E-mail: info@dfuntech.com

Inquiry

Copyright © 2023 DFUN (ZHUHAI) CO., LTD. Kodzero dzese dzakachengetwa. Privacy Policy | Sitemap