og

Iplathifomu Yokuphatha Yokuqapha Amandla Eyisipele Esihlanganisiwe

DFCS4200 | I-Intelligent Platform Yokuqapha Okuphelele Komjikelezo Wempilo Wamabhethri Nezinhlelo Zamandla

Ikhaya I-DFUN Multi-Loop Energy Meter

144 Izifunda. Uhlelo olulodwa lwe-DFUN Multi-Loop Energy Meter System.

Emklamweni ovamile wemitha eyodwa-ngesifunda, ukuqapha amasekhethi kagesi angu-144 kungase kudinge kufika kumamitha angu-144. I-DFUN multi-loop energy meter ihlanganisa ububanzi bokuqapha obufanayo ibe yisistimu eyodwa edidiyelwe ehlanganisa isilawuli esiyinhloko, amayunithi okulinganisa amamojula kanye nama-transformer amanje.


I-DFPM206 isekela iziteshi zokuqapha igatsha legatsha le-AC ezingafika ku-144, isiza izikhungo zedatha nezinye izinhlelo zamandla aminyana kakhulu zenze lula ukwakheka kwamaphaneli, ukuxhumana, ukugunyazwa kanye nokuphathwa kwamandla ezingeni legatsha.

Ukucaciswa okubalulekile
Kufikela kumashaneli angu-144 AC okuqapha umjikelezo wegatsha
Ukuxhumana kwe-Modbus RTU kanye ne-Modbus TCP
Ukuhlaziywa kwe-voltage kanye ne-harmonic yamanje kuze kufike ku-oda lama-63
Izinketho zokuqapha zomugqa ongenayo eyodwa noma ezimbili
Amayunithi egatsha e-Modular 24- noma 48
og

Iyini i-Multi-Loop Energy Meter?

Imitha ye-multi-loop energy iyisistimu yokulinganisa kagesi ephakathi nendawo eqapha amasekhethi amaningi angenayo namagatsha ngesilawuli esisodwa. Ngokungafani nemitha evamile evame ukukhonza isifunda esisodwa, isistimu ye-loop eminingi ihlanganisa isilawuli, amamojula okulinganisa nezinzwa zamanje ukuze kuqoqwe idatha kagesi yezinga lesifunda esakhiweni esisodwa esihlanganisiwe.

I-DFUN inikezela ngamamodeli azinikele we-multi-loop kuzo zombili izinhlelo ze-AC ne-DC:

DFPM201: kufika kumasekethe e-DC ayi-12

DFPM211: kufika kuma-45 isigaba esisodwa noma amasekhethi e-AC ezigaba ezintathu eziyi-15

DFPM206: kufika ku-144 AC amasekhethi egatsha


Le ndlela yokulinganisa ibaluleke kakhulu lapho iphrojekthi idinga ukuminyana kwesekethe ephezulu, indawo yephaneli elinganiselwe, ukuxhumana okuphakathi nendawo kanye nokubonakala okuningiliziwe kwezinga legatsha.

Kungani Usebenzisa I-DFUN Multi-Loop Energy Meter?

Khetha imitha yamandla ye-DFUN eneziluphu eziningi lapho amasekhethi kagesi amaningi kufanele aqashwe ngaphakathi kwephaneli elinganiselwe futhi aphathwe ngesakhiwo esisodwa sokuxhumana.
Esikhundleni sokuphinda imitha ephelele, isibonisi, isisetshenziswa sokuxhuma amandla kanye nekheli lenethiwekhi kuwo wonke amasekethe, i-DFUN ibeka phakathi ukulinganisa nokuxhumana. Lokhu kudala ukwakheka kwesistimu ehlanzekile, kunciphisa izingxenye eziphindaphindiwe futhi kwenza idatha ibe lula ukuhlanganisa endaweni yokuqapha amandla noma inkundla yokuphatha isakhiwo.

1. Shintshanisa i-architecture yemitha eyodwa-per-circuit

Ngokulinganisa okujwayelekile, igatsha ngalinye eligadiwe lingadinga imitha ehlukile. Kumasekhethi angu-144, lokho kungasho kufika kumadivayisi angu-144, izintambo eziphindaphindiwe kanye nenani elikhulu lamakheli okuxhumana.
I-DFPM206 iqapha kufika kumasekethe egatsha angu-144 njengohlelo olulodwa oludidiyelwe lwe-multi-loop. Uhlelo lusasebenzisa amayunithi okulinganisa ama-modular nama-transformer amanje, kodwa lususa isidingo sokufaka imitha ezimele eziphelele kuwo wonke amagatsha.

2. Khulisa ukuminyana kokuqapha


Amaphaneli okusabalalisa okuminyanisa okuphezulu avame ukuqukatha amasekhethi amaningi kunezakhiwo zamamitha ezivamile ezingamumatha kahle. I-DFUN ihlukanisa isilawuli kumamojula wokulinganisa wegatsha, okuvumela amasekhethi engeziwe ukuthi agadwe ngaphandle kokugcwalisa iphaneli ngobuso bemitha ngayinye.

3. Yenza lula ukuhlanganiswa kwesistimu


I-DFPM206 isekela kokubili i-Modbus RTU ne-Modbus TCP. Ngakho-ke izilinganiso zomjikelezo wegatsha zingahlanganiswa endaweni eyodwa yokuqapha amandla esikhundleni sokuphathwa njengeqoqo elikhulu lamamitha azimele angahlobene.

4. Thuthukisa ukubonakala kwezinga legatsha

Uhlelo lwe-DFPM206 lungaqapha amapharamitha kagesi kuwo wonke amasekethe angenayo namagatsha, okuhlanganisa:
I- etholakalayo iyatholakala voltage
Okwamanje
Amandla asebenzayo
Ukusetshenziswa kwamandla
Isici samandla
Imvamisa
Isimo sesekhethi
I-alamu nolwazi lomcimbi
Lokhu kwenza opharetha babone imithwalo engavamile, baqhathanise ukusebenza kwegatsha futhi bahlaziye ukusetshenziswa kwamandla ezingeni eliwusizo kakhulu kunesamba semitha eyodwa.

5. Sekela ukuhlaziywa kwekhwalithi yamandla


I-DFPM206 ihlinzeka ngokuhlaziywa kwe-voltage nokwamanje kwe-harmonic kuze kufike ku-oda lama-63. Lokhu kusiza amaqembu onjiniyela nawokusebenza ukuthi aphenye ukuhlanekezelwa kwe-waveform nezimo zekhwalithi yamandla ezindaweni ezibalulekile zokusabalalisa amandla.

6. Yehlisa ukufakwa kanye nomsebenzi wokuthuma


Ikhathalogi Yemitha ye-DFUN ibhala izinzuzo ezilandelayo zemitha yamandla ye-AC yeziteshi eziningi ze-DFPM211:
Isikhala sokufaka esingaphansi ngo-50%.
50% amahora wokufaka ambalwa
50% ngaphansi kwesikhathi sokulungisa amaphutha wesistimu
Lezi zibalo zisebenza ngokuqondile ekucushweni kwekhathalogi ye-DFPM211. Ukonga kwangempela kwephrojekthi kuncike kubuningi besekethe, ukwakheka kwamaphaneli, ukwakheka kwezintambo nezimo zesayithi.

Traditional Energy Meters vs. DFUN Multi-Loop Metering

Ohlelweni oluvamile lwemitha eyodwa-ngesifunda, amasekhethi agadwayo angu-144 angase adinge amamitha angama-144 ngamanye. UHLELO lwe-DFUN olunama-loop amaningi lusebenzisa isilawuli esimaphakathi kanye namayunithi egatsha ajwayelekile ukuze kuqashwe isikali sesekethe esifanayo ngokwakhiwa okukodwa okuhlanganisiwe.

UkuqhathanisaAmamitha ajwayelekileI-DFUN multi-loop system
I-Metering ArchitectureImitha eyodwa ezimele isekethe ngayinyeIsilawuli esimaphakathi esinamayunithi wokulinganisa we-modular
amayunithi
Iphrojekthi ye-144-circuitKufika ku-144 amamitha angawodwanaUkucushwa kwesistimu eyodwa ye-DFPM206
Umklamo wephaneliUkunqanyulwa kwamamitha okuphindaphindiwe noma amadivaysi e-DIN-railIsilawuli esihlangene namamojula wokulinganisa
IzintamboIzintambo zamandla nokuxhumana ziphindaphindiwe kumitha ngayinyeUkuxhumana okumaphakathi nokunwetshwa kwe-modular
Ukuphathwa kwedathaIzilinganiso zisatshalaliswa kumadivayisi amaningiIdatha yegatsha ihlelwe ngaphakathi kwesistimu eyodwa
UkunwetshwaEngeza enye imitha epheleleEngeza amamojula eziteshi ezihambisanayo ezingama-24- noma 48
EzokuxhumanaKuncike kumitha ngayinyeI-Modbus RTU ne-Modbus TCP ku-DFPM206
Ukuhlaziywa kwe-HarmonicKuncike kumamodeliKufika ku-oda lama-63 ku-DFPM206
IsondloImishini eminingi yamamitha azimele namakheliIsakhiwo sesistimu esihlanganisiwe
EzokuxhumanaKuncike kumitha ngayinyeI-Modbus RTU ne-Modbus TCP ku-DFPM206
Ukuhlaziywa kwe-HarmonicKuncike kumamodeliKufika ku-oda lama-63 ku-DFPM206
IsondloImishini eminingi yamamitha azimele namakheliIsakhiwo sesistimu esihlanganisiwe

Isifingqo: I-DFUN ayenzi nje imitha encane evamile. Ingena esikhundleni sokwakhiwa kwemitha eyodwa-per-circuit esatshalaliswe nge-modular multi-circuit monitoring system.

Iyiphi Imitha ye-DFUN Multi-Loop Energy Elungele Iphrojekthi Yakho?

企业微信截图_ 17883429678 8

I-DFPM201 Multi-Channel DC Energy Meter

Ividiyo ye-DFPM211 Yokulungisa iphutha

I-DFPM211 Multi-Channel AC Energy Meter

I-DFPM211 iyisistimu yokulinganisa ye-AC ehlangene yokuphathwa kwamandla ezokuxhumana, izikhungo zedatha nezinye izinhlelo zokusebenza ze-AC eziyiziyingi eziningi.


Ukucaciswa okubalulekile

Isekela amasekhethi esigaba esisodwa esingafika ku-45

Isekela kufika kumasekhethi ezigaba ezintathu eziyi-15

Ukunemba kwamandla kagesi nokunemba kwamanje: Ikilasi 0.5S

Ukunemba kwamandla: Ikilasi 1.0

RS485 ukuxhumana

Iphrothokholi ye-Modbus RTU


Izinzuzo zokufaka ezibhalwe phansi

Yonga u-50% wesikhala sokufaka

Igcina amahora okufaka angama-50%.

Yonga u-50% wesikhathi sokulungisa amaphutha wesistimu


Bes t kufanelekile

Ukusabalalisa kwe-AC ye-Medium-density

 Izinsiza zeTelecom

 Ukuphathwa kwamandla kwezohwebo

Ukusabalalisa kokusiza kwesikhungo sedatha


dfpm206-imitha

I-DFPM206 Multi-Channel AC Energy Meter

I-DFPM206 yakhelwe izikhungo zedatha namagumbi eziphakeli adinga ukuqoqwa kwedatha yamandla e-endpoint ephezulu nokugadwa kwesikhathi sangempela sokusatshalaliswa kwamandla.


Ukucaciswa okubalulekile

Umugqa owodwa noma emibili engenayo

Ukuqapha kokuphuma kwegatsha kwesiteshi okungu-144

24- noma 48-noma amamojula okuqapha amagatsha eziteshi

Izinketho ze-CT zegatsha: 50 A noma 100 A

Izinketho ze-CT ezicindezelayo noma ezihlukanisayo

Ukuqapha okungakhethi kanye nokuvuza kwamanje

Ukuhlaziywa kwe-voltage nokwamanje kwe-harmonic kuze kufike ku-oda lama-63

Okufakwayo kwedijithali okuyisishiyagalombili kanye nemiphumela emibili yedijithali

I-RJ45 eyodwa kanye nezindawo ezimbili zokuxhumana ze-RS485

I-Modbus RTU ne-Modbus TCP

I-HMI yesikrini esithintwayo ozikhethela sona

Amarekhodi omcimbi angaphezu kuka-5,000

Umbuzo wesehlakalo esingokomlando kanye nokuhlonzwa kwamaphutha

Ukufakwa kukaloliwe we-DIN


Ukunemba kokulinganisa

Amandla kagesi namanje: ±0.5%

Amandla namandla: ±1%

Imvamisa: ±0.02 Hz


Ifaneleka kakhulu

Izikhungo zedatha

Amakamelo eseva

Ukuqapha kwesekethe yegatsha eliminyana kakhulu

Amaphaneli abalulekile wokusabalalisa amandla

Ukuphathwa kwamandla okugcina


Isebenza kanjani i-DFPM206 144-Circuit System?

Uhlelo lwe-DFPM206 lwakhiwe ngezigaba ezine ezididiyelwe:

1. Ama-transformer amanje egatsha

Ama-transformer amanje akala amasekhethi aphumayo angawodwana. I-DFPM206 isekela izinketho ze-CT zegatsha ezingu-50 A nezingu-100 A ekulungiseni okubambayo noma okuhlukanisayo.

2. Amamojula okuqapha amagatsha

Amayunithi egatsha e-DFPM206 aqapha amasekhethi esigaba esisodwa angama-24 noma angama-48. Amamojula amaningi angahlanganiswa ukukala isistimu ibe nenani eliphakeme lamashaneli angama-144.

3. Isilawuli esikhulu

Isilawuli esiyinhloko se-DFPM206 siqapha umugqa owodwa noma emibili engenayo, sihlele idatha yegatsha futhi sinikeze ukuxhumana neplathifomu yokuqapha ekhuphuka nomfula.

4. Inkundla yokuqapha emaphakathi

Isilawuli sixhuma ekuqaphelweni kwamandla, ukuphathwa kwengqalasizinda yesikhungo sedatha, ukuphathwa kwezakhiwo noma inkundla yokuphatha amandla nge-Modbus TCP noma i-Modbus RTU.

Umphumela uba ukwakheka okukodwa kokuqapha okudidiyelwe kusuka kunzwa yamanje kuya endaweni yesikhulumi sokuphatha.

Izinzuzo Ezibalulekile Zezobuchwepheshe ze-DFUN Multi-Loop Metering

I-architecture yesistimu ye-modular


Khetha isilawuli, inombolo yamamojula okulinganisa kanye nokucushwa kwenzwa ngokuya ngokubala kwesekethe kwangempela. Lokhu kugwema ukuphoqelela yonke iphrojekthi kumitha engashintshi efanayo

Ukuxhumana okumaphakathi


Esikhundleni sokuphatha inqwaba noma amakhulu amakheli amamitha azimele, isistimu ye-DFUN multi-loop ihlela ukukalwa kwegatsha ngohlaka lokuxhumana oludidiyelwe.

Ukuqapha iphaneli yokuminyana okuphezulu


I-DFPM206 isekela amasekethe egatsha angafika kwangu-144, okuyenza ifanelekele izindawo eziminyene zokusabalalisa amandla lapho amamitha avamile edla isikhala esiningi kakhulu.

Ukufakwa komkhiqizo we-AC kanye ne-DC


Umndeni we-DFUN onama-loop amaningi umboza amasistimu e-telecom we-VDC angu-48, izinhlelo zokusebenza ze-AC ezinomthamo omaphakathi kanye nokuqapha kwegatsha le-AC elinabantu abaningi.

Inzwa yamanje eguquguqukayo


Ukucushwa okutholakalayo kwe-CT kuvumela isistimu ukuthi ihambisane nezidingo ezahlukene ezingenayo nezamanje zegatsha.

Ama-alamu esikhathi sangempela namarekhodi omcimbi


I-DFPM206 isekela ukuboniswa kwe-alamu yesikhathi sangempela, ukugawulwa kwemicimbi, imibuzo yedatha engokomlando kanye nokuxilongwa kwamaphutha nge-HMI yayo yokuzikhethela.

Izinhlelo zokusebenza

Izingosi ze-Telecom


Izikhungo Zedatha


Gada amasekhethi egatsha aminyana kakhulu, okuphakelayo okungenayo kanye nokusabalalisa kwamandla egumbi leseva. I-DFPM206 isiza opharetha ukuthi baqhathanise imithwalo, bahlonze amasekhethi angavamile futhi bahlanganise idatha yeleveli yegatsha nenkundla yokuqapha emaphakathi.


Amasayithi e-Telecom

Sebenzisa i-DFPM201 ku- -48 VDC ukulayisha noma i-DFPM211 ngokusabalalisa kwe-AC. Womabili amamodeli asekela ukulinganisa okumaphakathi kwezifunda eziningi ezindaweni zocingo ezicindezelwe yisikhala.

Izinsiza zezimboni

Beka endaweni eyodwa ukuqapha komthwalo namandla kuwo wonke amaphaneli wamandla wezifunda eziningi. Sebenzisa izilinganiso zezinga legatsha ukusekela ukuhlela amandla, ukugcinwa nokuhlaziywa kwamandla.

Izakhiwo Zokuhweba

Gada abaqashi, iphansi, amaqembu ezinto zokusebenza noma izindawo zokusebenza ngaphandle kokufaka imitha ephelele ehlukile yayo yonke isekethe egadiwe.

Amasistimu Amandla Abalulekile

Landelela amasekhethi angenayo naphumayo kumasistimu lapho isikhathi, ukubonakala kwe-alamu kanye nokufinyelela kwedatha okumaphakathi kuyizinto ezibalulekile zokusebenza.

Indlela yokukhetha i-Multi-Loop Energy Meter

Ngaphambi kokukhetha imodeli, qinisekisa imininingwane elandelayo yephrojekthi:


1.Ingabe uhlelo luyi-AC noma i-DC?
2.Mingaki imigqa engenayo okufanele igadwe?
3.Mangaki amasekhethi amagatsha anesigaba esisodwa noma ezigaba ezintathu adingekayo?
4.Yini imikhakha yamanje engenayo negatsha?
5.Yikuphi ukunemba kokulinganisa okudingekayo?
6.Ingabe ukuhlaziywa kwe-harmonic kuyadingeka?
7.Ingabe i-Modbus RTU, i-Modbus TCP noma kokubili kuyadingeka?
8.Ingabe i-HMI yesikrini esithintwayo sasendaweni iyadingeka?
9.Ingabe ukuqapha okungathathi hlangothi noma okuvuzayo kuyadingeka?
10.Singakanani i-DIN-rail kanye nesikhala sephaneli esitholakalayo?


I-DFUN ingasebenzisa lolu lwazi ukuze ikhethe isilawuli, amamojula egatsha, ama-CTs nokucushwa kokuxhumana kwephrojekthi.

FAQ

Q1: Uyini umehluko phakathi kwemitha ye-multi-loop energy kanye nemitha evamile?

A: Imitha yamandla evamile ivamise ukukala isekethe eyodwa. Imitha yamandla enamaluphu amaningi isebenzisa isilawuli esisodwa namayunithi wokulinganisa emojula ukuze igade amasekhethi amaningi angenayo namagatsha ngaphakathi kwesistimu eyodwa edidiyelwe.

I-Q2: Ingabe uhlelo olulodwa lwe-DFUN lungakwazi ukuqapha amasekethe angama-144?

Q3: Ingabe 'amasekhethi angu-144, isistimu eyodwa' isho imitha eyodwa ebonakalayo?

Q4: Iyiphi imodeli ye-DFUN esekela amasekhethi e-DC?

Q5: Iyiphi imodeli ye-DFUN esekela amasekhethi angama-45 AC?

Q6: Yiziphi izinqubo zokuxhumana ezisekelwa yi-DFPM206?

Q7: Ingabe i-DFPM206 ingahlaziya ama-harmonics?

Q8: Ingabe i-DFPM206 ilungele izikhungo zedatha?

Q9: Ngisithola kanjani isiphakamiso semitha ye-loop eningi ye-DFUN?

Isiphetho


I-DFUN multi-loop energy metres ithatha indawo yomklamo osabalalisiwe wemitha eyodwa-per-circuit ngesakhiwo sokuqapha esimaphakathi nesemojuli. I-DFPM201 ihlanganisa amasekhethi e-DC afika kwangu-12, i-DFPM211 ihlanganisa amasekhethi e-AC esigaba esisodwa esingafika kwangu-45 noma angu-15 ezigaba ezintathu, kanye nezikali ze-DFPM206 kumasekethe egatsha angu-144 AC.


Ezikhungweni zedatha, amasayithi e-telecom namanye amasistimu wamandla aminyana kakhulu, le ndlela yenza ukwakheka kwamaphaneli kube lula, ihlanganise ukuxhumana futhi inikeze idatha yamandla ewusizo kakhulu yezinga legatsha.

Amabhulogi Ahlobene

  • Ukumelana Kwangaphakathi Kwebhethri ye-UPS: Kufanele Uyimisele Nini?
    Ukumelana kwangaphakathi kungenye yezinkomba zakuqala ezinokwethenjelwa kakhulu zempilo yebhethri ye-VRLA, kodwa ayikho inombolo eyodwa yendawo yonke ekutshela ukuthi ulishintsha nini ibhethri — ukufunda kusho okuthile kuphela ngokumelene nesisekelo seseli uqobo. Lesi sihloko sephula umthetho wokushintsha ongu-50%-ngenhla-oyisisekelo, isheke lokuchezuka kweseli kuya kuseli elingu-20–30% ukuze libone iyunithi elibambekayo, nokuthi kungani ukweqa okungazelelwe kokumelana kubaluleke ngaphezu kwenani eliphelele eliphezulu. Iphinde ihlanganise ukuthi kungani ukumelana kukodwa kungenele - ukumatanisa nokuhlolwa kwamandla e-float, ukuhlolwa kokukhishwa komthamo, nokuhlola okubukwayo - nokuthi inkundla yokuqapha ibhethri ehlanganisiwe ye-DFUN kanye nenkundla yokuhlola umthamo yenza kanjani ukulandelelwa komkhawulo kuyo yonke iyunithi yezinhlamvu.
    Ucwaningo lwesigameko
  • Amasistimu Wokuqapha Ibhethri Angcono Kakhulu Wesikhungo Sedatha
    Isikhungo sedatha siyingxenye ebalulekile yanoma yiliphi ibhizinisi emhlabeni wanamuhla oqhutshwa idatha. Kube khona ukwanda okukhulu kwezidingo zokugcinwa kwedatha nezidingo zokuphatha phakathi neshumi leminyaka elidlule, okuholela ekwenyukeni kobubanzi, isikali, nobunkimbinkimbi bezikhungo zedatha. Ngaphansi kwalesi simo, ukuqapha okude kwe-solut
    I-athikili Yenani
  • I-UPS Battery Management & Monitoring System Yezikhumulo Zezindiza | Ukuqinisekisa Amandla Athembekile Esikhumulweni Sezindiza SaseSingapore
    Ezindaweni ezibalulekile zemishini ezifana nezikhumulo zezindiza, izikhungo zedatha, namakhampasi amakhulu, ukwethembeka kwamandla okulondoloza kubalulekile. Ukuphatha izinkulungwane zamabhethri ezinhlelweni ze-UPS sekuya ngokuya kuba nzima, nezindlela zokunakekela ezijwayelekile azisanele.
    Ucwaningo lwesigameko

Thola i-DFUN Multi-Loop Metering Proposal

Sithumele isibalo sakho sesekhethi, umdwebo womugqa owodwa kanye nezidingo zokuxhumana. Ithimba lethu lizoncoma isilawuli esifanele se-DFUN, amamojula okulinganisa nezinzwa zamanje.

Isixuku: +86- 15919182362

I-imeyili: info@dfuntech.com

Uphenyo

Copyright © 2023 DFUN (ZHUHAI) CO., LTD. Wonke Amalungelo Agodliwe. Inqubomgomo yobumfihlo | Imephu yesayithi