og

Backup Power Monitoring Management Platform a wɔaka abom

DFCS4200 na ɛwɔ hɔ | Nyansa kwan a Ɛfa Batere ne Tumi Nhyehyɛe Ho Asetra mu Nneɛma a Ɛkɔ Akyiri So

Fie DFUN Multi-Loop Ahoɔden Mita

144 Amansin Amansin. DFUN Multi-Loop Ahoɔden Mita Nhyehyɛe biako.

Wɔ nhyehyɛe a wɔtaa de yɛ mita biako wɔ amansin biara mu mu no, ebia anyinam ahoɔden akwansin 144 a wɔbɛhwɛ so no behia mita ankorankoro a ɛkɔ soro kodu 144. DFUN multi-loop ahoɔden mita ka monitoring scope koro no ara bom yɛ no nhyehyɛe biako a wɔayɛ no biako a ɛyɛ controller titiriw, modular measurement units ne current transformers.


DFPM206 boa AC branch-circuit monitoring channels a ɛkɔ soro kodu 144, ɛboa data centers ne high-density power systems foforɔ ma panel design, nkitahodi, commissioning ne branch-level energy management yɛ mmerɛw.

Nsɛm atitiriw a wɔakyerɛkyerɛ mu
AC branch-circuit monitoring akwan a ɛkɔ soro kodu 144
Modbus RTU ne Modbus TCP nkitahodi
Voltage ne current harmonic nhwehwɛmu kɔsi 63rd order
Incoming-line monitoring akwan baako anaa mmienu
Modular 24- anaa 48-channel baa dwumadibea akuw
og

Dɛn Ne Multi-Loop Ahoɔden Mita?

Multi-loop energy meter yɛ anyinam ahoɔden susuw nhyehyɛe a ɛwɔ mfinimfini a ɛnam controller biako so hwɛ circuit ahorow pii a ɛba ne nkorabata so. Nea ɛnte sɛ mita a wɔtaa de di dwuma a ɛtaa som ɔmansin biako no, multi-loop nhyehyɛe ka controller, measurement modules ne current sensors bom de boaboa circuit-level anyinam ahoɔden data ano wɔ nhyehyɛe biako a wɔayɛ no biako mu.

DFUN de multi-loop models a wɔatu ho ama ma AC ne DC nhyehyɛe nyinaa ma:

DFPM201: ɛkɔ DC amansin 12

DFPM211: AC circuits a ɛkɔ soro kodu 45 a ɛwɔ phase baako anaa 15 a ɛwɔ phase mmiɛnsa

DFPM206: ɛkɔ AC baa dwumadibea amansin 144


Saa modular kwan yi som bo titiriw bere a adwuma bi hwehwɛ sɛ circuit density a ɛkorɔn, panel space kakraa bi, nkitahodi a ɛwɔ mfinimfini ne branch-level visibility a ɛkɔ akyiri.

Dɛn Nti na Fa DFUN Multi-Loop Ahoɔden Mita Di Dwuma?

Paw DFUN multi-loop ahoɔden mita bere a ɛsɛ sɛ wɔhwɛ anyinam ahoɔden akwan pii so wɔ panel footprint a anohyeto wom mu na wɔfa nkitahodi nhyehyɛe biako so di ho dwuma.
Sɛ anka wɔbɛsan ayɛ mita, ɔyɛkyerɛ, tumi nkitahodi a ɛboa ne ntwamutam address a edi mũ ama ɔmansin biara no, DFUN de susudua ne nkitahodi si baabiara. Eyi ma nhyehyɛe nhyehyɛe a ɛho tew ba, ɛtew nneɛma a wɔtaa yɛ no so na ɛma ɛyɛ mmerɛw sɛ wɔde data bɛka tumi a wɔhwɛ so anaa ɔdan sohwɛ nhyehyɛe mu.

1. Sesa mita biako wɔ amansin biara mu

Sɛ wɔde mita a wɔtaa de di dwuma di dwuma a, ebia baa dwumadibea biara a wɔhwɛ so no behia mita a ɛyɛ soronko. Wɔ amansin 144 mu no, ɛno betumi akyerɛ mfiri ankorankoro a ɛkɔ soro kodu 144, nhama a wɔde hyɛ mu mpɛn pii ne nkitahodi address dodow bi.
DFPM206 hwɛ baa dwumadibea amansin a ɛkɔ soro kodu 144 sɛ nhyehyɛe biako a wɔayɛ no biako a ɛwɔ multi-loop. Nhyehyɛe no da so ara de modular measurement units ne current transformers di dwuma, nanso eyi hia a ehia sɛ wɔde mita a egyina hɔ ma nea edi mũ sisi baa dwumadibea biara mu no fi hɔ.

2. Ma monitoring density nkɔ soro


Mpɛn pii no, amansin pii na ɛwɔ afiri a wɔde kyekyɛ nneɛma a ɛwɔ density kɛse mu sen sɛnea mita nhyehyɛe a wɔtaa de di dwuma no betumi de ahyɛ mu yiye. DFUN tetew controller no mu fi baa dwumadibea susudua module ahorow no ho, na ɛma wotumi hwɛ amansin pii so a wɔmfa mita anim ankorankoro nhyɛ panel no ma.

3. Ma nhyehyɛe a wɔde ka bom yɛ mmerɛw


DFPM206 boa Modbus RTU ne Modbus TCP nyinaa. Enti wobetumi de nkorabata-kwansin susudua ayɛ biako wɔ tumi a wɔhwɛ so wɔ beae a ɛwɔ mfinimfini sen sɛ wɔbɛhwɛ so sɛ mita ahorow a egyina hɔ ma a ɛne ne ho nni abusuabɔ a wɔaboaboa ano kɛse.

4. Ma sɛnea wotumi hu nneɛma wɔ baa dwumadibea no tu mpɔn

DFPM206 nhyehyɛe no tumi hwɛ anyinam ahoɔden nsusuwii ahorow wɔ amansin a ɛba ne nkorabata amansin mu, a nea ɛka ho ne:
Nneɛma a ɛma ahoɔden
Mprempren de
Tumi a ɛyɛ adwuma
Ahoɔden a wɔde di dwuma
Tumi a wɔde yɛ ade
Mpɛn dodow a wɔyɛ
Ɔmansin tebea
Alarm ne nsɛm a esisi ho nsɛm
Eyi ma adwumayɛfo tumi hu adesoa a ɛnyɛ ne kwan so, de toto baa dwumadibea adwumayɛ ho na wɔhwehwɛ ahoɔden a wɔde di dwuma mu wɔ ɔkwan a mfaso wɔ so sen mita biako a ɛyɛ ne nyinaa.

5. Boa tumi-su nhwehwɛmu


DFPM206 ma voltage ne mprempren harmonic nhwehwɛmu kosi 63rd nhyehyɛe. Eyi boa mfiridwuma ne adwumayɛ akuw ma wɔhwehwɛ asorɔkye nsusuwii a wɔkyinkyim ne tumi-su tebea horow mu wɔ tumi-kyekyɛ tebea horow a ɛho hia mu.

6. Tew installation ne commissioning adwuma so


DFUN Mita Katalog no kyerɛw mfaso a edidi so yi ma DFPM211 AC ahoɔden mita a ɛwɔ akwan pii so:
50% a ɛsua sɛ wɔde besisi hɔ
Nnɔnhwerew a wɔde si hɔ no sua 50%
50% sua bere a wɔde yɛ nhyehyɛe no debugging
Saa akontabuo yi fa DFPM211 katalog nhyehyeɛ no ho titire. Nnwuma no sikakorabea ankasa gyina ɔmansin dodow, panel nhyehyɛe, wiring nhyehyɛe ne beae no tebea so.

Amanneɛ kwan so Ahoɔden Mita vs. DFUN Multi-Loop Mita

Wɔ nhyehyɛe a wɔtaa de di dwuma a ɛyɛ mita biako wɔ amansin biara mu mu no, ebia amansin 144 a wɔhwɛ so behia mita ankorankoro a ɛkɔ soro kodu 144. DFUN multi-loop nhyehyɛe de centralized controller ne modular branch units di dwuma de hwɛ circuit scale koro no ara denam architecture biako a wɔayɛ no biako so.

NtotohoMita ahorow a wɔtaa de di dwumaDFUN nhyehyɛe a ɛwɔ loop pii
Mita ho nhyehyɛeMita biako a egyina hɔ ma ne ho wɔ ɔmansin biara muCentral controller a ɛwɔ modular susuw akuw
unit ahorow a ɛwɔ hɔ
144-amansin adwumaƐkɔ soro kodu mita ankorankoro 144DFPM206 nhyehyɛe nhyehyɛe biako
Panel nhyehyɛeMita a wɔatwa no mpɛn pii anaa DIN-rail mfiriCompact controller ne susuw module ahorow
Wiring a wɔde hyɛ muTumi ne nkitahodi nhama a wɔsan yɛ bio wɔ mita biara hoCentralized nkitahodi a modular ntrɛwmu
Data a wɔde di dwumaNsusuwii ahorow a wɔkyekyɛ wɔ mfiri pii soBaa dwumadibea data a wɔahyehyɛ wɔ nhyehyɛe biako mu
NtrɛwmuFa mita foforo a edi mũ ka hoFa module ahorow a ɛwɔ akwan 24 anaa 48 a ɛne no hyia ka ho
Nkitahodi ho nsɛmEgyina ankorankoro mita biara soModbus RTU ne Modbus TCP wɔ DFPM206 so
Harmonic nhwehwɛmuNhwɛsode a egyina soƐkɔsi 63rd order wɔ DFPM206 so
NsiesieMita mfiri ne address ahorow pii a wɔde wɔn hoNhyehyɛe nhyehyɛe a wɔayɛ no biako
Nkitahodi ho nsɛmEgyina ankorankoro mita biara soModbus RTU ne Modbus TCP wɔ DFPM206 so
Harmonic nhwehwɛmuNhwɛsode a egyina soƐkɔsi 63rd order wɔ DFPM206 so
NsiesieMita mfiri ne address ahorow pii a wɔde wɔn hoNhyehyɛe nhyehyɛe a wɔayɛ no biako

Nsɛm a wɔaboaboa ano: DFUN nyɛ mita ketewaa bi a wɔtaa de di dwuma kɛkɛ. Ɛde modular multi-circuit monitoring system si nhyehyɛe a wɔakyekyɛ a ɛyɛ mita biako wɔ amansin biara mu ananmu.

DFUN Multi-Loop Energy Meter bɛn na Ɛfata Ma Wo Dwumadie?

企业微信截图_ 17883429678 8. Ɔde ne nsa kyerɛɛ ne so

DFPM201 Multi-Channel DC Ahoɔden Mita

DFPM211 Video a Wɔreyɛ no Debugging

DFPM211 Multi-Channel AC Ahoɔden Mita

DFPM211 yɛ modular AC mita nhyehyɛe a ɛyɛ ketewa a wɔde di dwuma ma telecom ahoɔden ho nhyehyɛe, data mmeae ne AC dwumadie afoforo a ɛwɔ amansin pii mu.


Nsɛm atitiriw a wɔakyerɛkyerɛ mu

Ɛboa circuits a ɛkɔ soro kodu 45 a ɛwɔ phase baako

Ɛboa amansin a ɛwɔ fase abiɛsa a ɛkɔ soro kodu 15

Voltage ne mprempren pɛpɛɛpɛyɛ: Class 0.5S

Ahoɔden a ɛyɛ pɛpɛɛpɛ: Adesua 1.0

RS485 nkitahodi

Modbus RTU nhyehyeɛ


Mfaso a ɛwɔ instɔlehyɛn a wɔakyerɛw ato hɔ

Ɛkora 50% a wɔde besisi hɔ

Ɛkora nnɔnhwereɛ a wɔde hyehyɛ so 50%

Ɛkora 50% system debugging bere so


Best t fata ma

AC a wɔkyekyɛ no a ɛyɛ medium-density

Telecom adwumayɛbea ahorow

Aguadi mu ahoɔden a wɔde di dwuma

Data-center aboafoɔ nkyekyɛmu


dfpm206-mita a ɛwɔ hɔ

DFPM206 Multi-Channel AC Ahoɔden Mita

Wɔayɛ DFPM206 ama data centers ne server rooms a ɛhia high-density endpoint ahoɔden data a wɔboaboa ano ne bere ankasa mu tumi-kyekyɛ so hwɛ.


Nsɛm atitiriw a wɔakyerɛkyerɛ mu

Ntrɛwmu biako anaa abien a ɛba

Maximum 144-channel baa dwumadibea a ɛba no sohwɛ

24- anaa 48-channel baa dwumadibea nhwehwɛmu module ahorow

Baa dwumadibea CT a wobetumi apaw: 50 A anaa 100 A

Clamp-on anaa split-core CT a wobɛpaw

Nhwɛsoɔ a ɛfa neutral ne leakage-current a wɔpaw

Voltage ne mprempren harmonic nhwehwɛmu kosi 63rd order

Digital inputs awotwe ne digital outputs mmienu

RJ45 baako ne RS485 nkitahodiɛ ntam nkitahodiɛ mmienu

Modbus RTU ne Modbus TCP

HMI a ɛwɔ touchscreen a wopɛ

Nsɛm a esisii ho kyerɛwtohɔ bɛboro 5,000

Abakɔsɛm mu nsɛm a ɛsisiiɛ ho asɛmmisa ne mfomsoɔ a wɔhwehwɛ

DIN-keteke a wɔde si hɔ


Nsusuwii a ɛyɛ pɛpɛɛpɛ

Voltage ne mprempren: ±0.5% .

Ahoɔden ne ahoɔden: ±1% .

Mpɛn pii no: ±0.02 Hz


Nea ɛfata yiye ma

Data mmeae a wɔde nsɛm gu

Server adan a wɔde ma

High-density baa dwumadibea amansin sohwɛ

Tumi-kyekyɛ panels a ɛho hia

Endpoint ahoɔden a wɔde di dwuma


Ɔkwan Bɛn so na DFPM206 144-Circuit System no Yɛ Adwuma?

Wɔasisi DFPM206 nhyehyɛe bi wɔ ntoatoaso anan a wɔayɛ no biako mu:

1. Baa dwumadibea mprempren transformers

Mprempren transformers susuw ankorankoro outgoing circuits. DFPM206 boa 50 A ne 100 A baa dwumadibea CT akwan horow wɔ clamp-on anaa split-core nhyehyɛe ahorow mu.

2. Baa dwumadibea ahorow a wɔhwɛ so module ahorow

DFPM206 baa dwumadibea akuw no hwɛ amansin 24 anaa 48 a ɛwɔ fase biako so. Wobetumi aka module ahorow pii abom de ayɛ nhyehyɛe no kɛse akodu baa dwumadibea akwan 144 a ɛboro so.

3. Ɔhwɛfo titiriw

DFPM206 main controller no hwɛ lines baako anaa mmienu a ɛba, hyehyɛ branch data na ɛma nkitahodie ne upstream monitoring platform.

4. Mfinimfini hwɛbea a wɔde hwɛ nneɛma so

Controller no nam Modbus TCP anaa Modbus RTU so di nkitaho kɔ tumi a wɔhwɛ so, data-center infrastructure management, ɔdan sohwɛ anaa ahoɔden sohwɛ platform so.

Nea afi mu aba ne nhyehyɛe biako a wɔayɛ no biako a wɔde hwɛ nneɛma so fi mprempren sensor no so kosi management platform no so.

Mfiridwuma mu Mfaso Titiriw a Ɛwɔ DFUN Multi-Loop Metering so

Modular nhyehyɛe nhyehyɛe


Paw controller, dodow a susuw modules ne sensor nhyehyɛe sɛnea ankasa circuit count. Eyi kwati sɛ wɔbɛhyɛ adwuma biara ma akɔ mita koro no ara a wɔahyɛ da ayɛ mu

Nkitahodi a ɛwɔ mfinimfini


Sɛ anka ɛbɛhwɛ mita address ahorow du du anaa ɔhaha pii a ɛde ne ho so no, DFUN multi-loop nhyehyɛe bi nam nkitahodi nhyehyɛe a wɔayɛ no biako so hyehyɛ baa dwumadibea susuw.

High-density panel a wɔde hwɛ nneɛma so


DFPM206 boa baa dwumadibea amansin a ɛkɔ soro kodu 144, na ɛma ɛfata ma tumi-kyekyɛ mmeae a ɛyɛ den a mita a wɔtaa de di dwuma no gye baabi dodo.

AC ne DC nneɛma a wɔde kata so


DFUN multi-loop abusua no kata -48 VDC telecom nhyehyɛe, medium-density AC applications ne high-density AC baa dwumadibea hwɛ so.

Mprempren nkate a ɛyɛ mmerɛw


CT nhyehyɛe ahorow a ɛwɔ hɔ no ma nhyehyɛe no ne ahwehwɛde ahorow a ɛba ne baa dwumadibea mprempren ahwehwɛde ahorow hyia.

Bere ankasa mu alarm ne nsɛm a esisi ho kyerɛwtohɔ


DFPM206 boa bere ankasa mu alarm kyerɛ, nsɛm a esisi ho kyerɛwtohɔ, abakɔsɛm mu data nsɛmmisa ne mfomso nhwehwɛmu denam ne HMI a wopɛ so.

Nnwuma a Wɔde Di Dwuma

Telecom nsɛmma nhoma ahorow


Data Centers a Wɔde Di Dwuma


Hwɛ baa dwumadibea amansin a ɛwɔ density kɛse, aduan a ɛba ne server-room ahoɔden kyekyɛ so. DFPM206 boa adwumayɛfoɔ ma wɔde adesoa toto ho, hunu amansin a ɛnyɛ ne kwan so na wɔde baa dwumadibea-gyinabea data ne centralized monitoring platform bom.


Telecom Nsɛmma Nhoma

Fa DFPM201 di dwuma ma -48 VDC adesoa anaa DFPM211 ma AC kyekyɛ. Nhwɛsoɔ mmienu no nyinaa boa centralized multi-circuit susudua wɔ ahunmu-constrained telecom mmeaeɛ.

Nnwumayɛbea Ahorow

Centralize adesoa ne ahoɔden sohwɛ wɔ multi-circuit tumi panels. Fa baa dwumadibea susudua di dwuma de boa tumi nhyehyɛe, nsiesie ne ahoɔden nhwehwɛmu.

Adan a Wɔde Di Dwuma

Hwɛ wɔn a wɔagye adan, fam, nnwinnade akuw anaa mmeae a wɔyɛ adwuma a womfa mita a edi mũ a ɛyɛ soronko nsi hɔ mma ɔmansin biara a wɔhwɛ so.

Tumi Nhyehyɛe a Ɛho Hia

Track incoming ne outgoing circuits wɔ systems a uptime, alarm visibility ne centralized data access yɛ adwumayɛ mu nneɛma a ɛho hia.

Sɛnea Wobɛpaw Multi-Loop Ahoɔden Mita

Ansa na wobɛpaw nhwɛsode bi no, si adwuma no ho nsɛm a edidi so yi so dua:


1.So nhyehyɛe no yɛ AC anaa DC?
2.Ntrɛwmu ahe na ɛsɛ sɛ wɔhwɛ so?
3.Fase biako anaa abiɛsa baa dwumadibea amansin dodow ahe na ɛho hia?
4.Dɛn ne incoming ne branch mprempren ranges?
5.Dɛn na wɔhwehwɛ sɛ wɔyɛ susudua pɛpɛɛpɛ?
6.So ɛho hia sɛ wɔyɛ harmonic analysis?
7.So Modbus RTU, Modbus TCP anaa abien no nyinaa ho hia?
8.So ɛho hia sɛ wonya mpɔtam hɔ touchscreen HMI?
9.So neutral anaasɛ leakage-mprempren monitoring ho hia?
10.DIN-rail ne panel space dodow ahe na ɛwɔ hɔ?


DFUN betumi de saa nsɛm yi apaw controller, branch modules, CTs ne nkitahodi nhyehyɛe ama adwuma no.

FAQ

Q1: Nsonsonoe bɛn na ɛda multi-loop energy meter ne amanne kwan so mita ntam?

A: Mpɛn pii no, ahoɔden mita a wɔtaa de di dwuma no susuw ɔmansin biako. Multi-loop ahoɔden mita de controller biako ne modular measurement units di dwuma de hwɛ incoming ne branch circuits pii wɔ nhyehyɛe biako a wɔayɛ no biako mu.

Q2: So DFUN nhyehyɛe biako betumi ahwɛ amansin 144 so?

Q3: So '144 circuits, nhyehyɛe biako' kyerɛ honam fam mita biako?

Q4: DFUN model bɛn na ɛboa DC circuits?

Q5: DFUN model bɛn na ɛboa AC circuits 45?

Q6: Nkitahodi nhyehyɛe bɛn na DFPM206 boa?

Q7: So DFPM206 betumi ahwehwɛ harmonics mu?

Q8: So DFPM206 fata ma data centers?

Q9: Mɛyɛ dɛn anya DFUN multi-loop meter proposal?

Awie


DFUN ahoɔden mita ahorow a ɛwɔ loop pii no de mita biako-biara-circuit nhyehyɛe a wɔakyekyɛ no si mfinimfini ne modular monitoring architecture ananmu. DFPM201 kata DC amansin a ɛkɔ soro kodu 12, DFPM211 kata AC amansin a ɛkɔ soro kodu 45 a ɛwɔ phase biako anaa 15 a ɛwɔ phase abiɛsa, na DFPM206 kata AC nkorabata amansin 144 so.


Wɔ data centers, telecom sites ne high-density power systems afoforo ho no, saa kwan yi ma panel design yɛ mmerɛw, ɛhyɛ nkitahodi mu den na ɛma branch-level ahoɔden data a mfaso wɔ so kɛse.

Blog ahorow a ɛfa ho

  • UPS Battery Internal Resistance: Bere Bɛn na Ɛsɛ sɛ Wosesa?
    Mfinimfini ahoɔden a ɛko tia yɛ VRLA batere akwahosan ho nsɛnkyerɛnne a edi kan a wotumi de ho to so sen biara no mu biako, nanso amansan nɔma biako biara nni hɔ a ɛkyerɛ wo bere a ɛsɛ sɛ wosesa batere — akenkan no kyerɛ biribi a ɛne nkwammoaa no ankasa mfiase nhyia nkutoo. Saa asɛm yi bubu 50%-above-baseline replacement mmara, 20–30% cell-to-cell deviation check a wɔde hu unit a ɛka akyi, ne nea enti a mpofirim ahuru wɔ resistance mu ho hia sen absolute value a ɛkorɔn. Ɛsan nso ka nea enti a resistance nkutoo nnɔɔso — pairing no ne float voltage checks, capacity discharge testing, ne visual inspection — ne sɛnea DFUN’s integrated battery monitoring ne capacity testing platform no ma threshold tracking yɛ adwuma wɔ string mũ no nyinaa so.
    Nsɛm a Wɔayɛ ho Nhwehwɛmu
  • Battery Monitoring nhyehyɛe a eye sen biara ma Data Center
    Data center yɛ ade titiriw a ɛwɔ adwuma biara mu wɔ nnɛ wiase a data na ɛkɔ so no mu. Nkɔanim kɛse aba wɔ data a wɔkora so ne ne sohwɛ ahiade mu wɔ mfe du a atwam no mu, na ɛde nkɔanim aba wɔ data mmeae ahorow no kɛse, ne kɛse, ne nea ɛyɛ den mu. Wɔ saa tebea yi ase no, akyirikyiri hwɛ solut
    Botae Asɛmti
  • UPS Battery Management & Monitoring System a Wɔde Hwɛ Wimhyɛn Gyinabea | Tumi a Wotumi De Ho To So a Wɔbɛhwɛ Ma Wɔ Singapore Wimhyɛn Gyinabea
    Wɔ mmeae a ɛho hia wɔ asɛmpatrɛw adwuma te sɛ wimhyɛn gyinabea, data mmeae, ne sukuupɔn akɛse mu no, ahoɔden a wɔde sie ho ahotoso ho hia. Batere mpempem pii a wɔbɛhwɛ so wɔ UPS nhyehyɛe ahorow mu no abɛyɛ nea ɛyɛ den kɛse, na akwan a wɔfa so siesie no atetesɛm no nnɔɔso bio.
    Nsɛm a Wɔayɛ ho Nhwehwɛmu

Nya DFUN Multi-Loop Mita Ho Nsusuwii

Fa wo circuit count, single-line diagram ne nkitahodi ahwehwɛde ahorow mena yɛn. Yɛn kuw no bɛkamfo DFUN controller a ɛfata, susudua module ne mprempren sensor ahorow akyerɛ.

Nsɛm a wɔka kyerɛ:+86- 15919182362

E-mail: info@dfuntech.com

Nhwehwɛmu

Nneɛma a Wɔde Yɛ Adwuma © 2023 DFUN (ZHUHAI) CO., LTD. Hokwan ahorow nyinaa wɔ hɔ. Nsɛm a Wɔde Sie | Sitemap a Wɔde Di Dwuma