144 Amansin Amansin. DFUN Multi-Loop Ahoɔden Mita Nhyehyɛe biako.
Wɔ nhyehyɛe a wɔtaa de yɛ mita biako wɔ amansin biara mu mu no, ebia anyinam ahoɔden akwansin 144 a wɔbɛhwɛ so no behia mita ankorankoro a ɛkɔ soro kodu 144. DFUN multi-loop ahoɔden mita ka monitoring scope koro no ara bom yɛ no nhyehyɛe biako a wɔayɛ no biako a ɛyɛ controller titiriw, modular measurement units ne current transformers.
DFPM206 boa AC branch-circuit monitoring channels a ɛkɔ soro kodu 144, ɛboa data centers ne high-density power systems foforɔ ma panel design, nkitahodi, commissioning ne branch-level energy management yɛ mmerɛw.

Dɛn Ne Multi-Loop Ahoɔden Mita?
Multi-loop energy meter yɛ anyinam ahoɔden susuw nhyehyɛe a ɛwɔ mfinimfini a ɛnam controller biako so hwɛ circuit ahorow pii a ɛba ne nkorabata so. Nea ɛnte sɛ mita a wɔtaa de di dwuma a ɛtaa som ɔmansin biako no, multi-loop nhyehyɛe ka controller, measurement modules ne current sensors bom de boaboa circuit-level anyinam ahoɔden data ano wɔ nhyehyɛe biako a wɔayɛ no biako mu.
DFUN de multi-loop models a wɔatu ho ama ma AC ne DC nhyehyɛe nyinaa ma:
DFPM201: ɛkɔ DC amansin 12
DFPM211: AC circuits a ɛkɔ soro kodu 45 a ɛwɔ phase baako anaa 15 a ɛwɔ phase mmiɛnsa
DFPM206: ɛkɔ AC baa dwumadibea amansin 144
Saa modular kwan yi som bo titiriw bere a adwuma bi hwehwɛ sɛ circuit density a ɛkorɔn, panel space kakraa bi, nkitahodi a ɛwɔ mfinimfini ne branch-level visibility a ɛkɔ akyiri.
Amanneɛ kwan so Ahoɔden Mita vs. DFUN Multi-Loop Mita
Wɔ nhyehyɛe a wɔtaa de di dwuma a ɛyɛ mita biako wɔ amansin biara mu mu no, ebia amansin 144 a wɔhwɛ so behia mita ankorankoro a ɛkɔ soro kodu 144. DFUN multi-loop nhyehyɛe de centralized controller ne modular branch units di dwuma de hwɛ circuit scale koro no ara denam architecture biako a wɔayɛ no biako so.
| Ntotoho | Mita ahorow a wɔtaa de di dwuma | DFUN nhyehyɛe a ɛwɔ loop pii |
| Mita ho nhyehyɛe | Mita biako a egyina hɔ ma ne ho wɔ ɔmansin biara mu | Central controller a ɛwɔ modular susuw akuw |
| unit ahorow a ɛwɔ hɔ | ||
| 144-amansin adwuma | Ɛkɔ soro kodu mita ankorankoro 144 | DFPM206 nhyehyɛe nhyehyɛe biako |
| Panel nhyehyɛe | Mita a wɔatwa no mpɛn pii anaa DIN-rail mfiri | Compact controller ne susuw module ahorow |
| Wiring a wɔde hyɛ mu | Tumi ne nkitahodi nhama a wɔsan yɛ bio wɔ mita biara ho | Centralized nkitahodi a modular ntrɛwmu |
| Data a wɔde di dwuma | Nsusuwii ahorow a wɔkyekyɛ wɔ mfiri pii so | Baa dwumadibea data a wɔahyehyɛ wɔ nhyehyɛe biako mu |
| Ntrɛwmu | Fa mita foforo a edi mũ ka ho | Fa module ahorow a ɛwɔ akwan 24 anaa 48 a ɛne no hyia ka ho |
| Nkitahodi ho nsɛm | Egyina ankorankoro mita biara so | Modbus RTU ne Modbus TCP wɔ DFPM206 so |
| Harmonic nhwehwɛmu | Nhwɛsode a egyina so | Ɛkɔsi 63rd order wɔ DFPM206 so |
| Nsiesie | Mita mfiri ne address ahorow pii a wɔde wɔn ho | Nhyehyɛe nhyehyɛe a wɔayɛ no biako |
| Nkitahodi ho nsɛm | Egyina ankorankoro mita biara so | Modbus RTU ne Modbus TCP wɔ DFPM206 so |
| Harmonic nhwehwɛmu | Nhwɛsode a egyina so | Ɛkɔsi 63rd order wɔ DFPM206 so |
| Nsiesie | Mita mfiri ne address ahorow pii a wɔde wɔn ho | Nhyehyɛe nhyehyɛe a wɔayɛ no biako |
Nsɛm a wɔaboaboa ano: DFUN nyɛ mita ketewaa bi a wɔtaa de di dwuma kɛkɛ. Ɛde modular multi-circuit monitoring system si nhyehyɛe a wɔakyekyɛ a ɛyɛ mita biako wɔ amansin biara mu ananmu.
DFUN Multi-Loop Energy Meter bɛn na Ɛfata Ma Wo Dwumadie?

DFPM201 Multi-Channel DC Ahoɔden Mita
Wɔayɛ DFPM201 ama -48 VDC dwumadie te sɛ telecom site billing systems ne DC load management.
Nsɛm atitiriw a wɔakyerɛkyerɛ mu
Ɛboa DC circuits a ɛkɔ soro kodu 12 a ɛwɔ phase baako
Voltage ne current a ɛyɛ pɛpɛɛpɛ: Class 0.5S
Ahoɔden a ɛyɛ pɛpɛɛpɛ: Adesua 1.0
RS485 nkitahodi
Modbus RTU nhyehyeɛ
Modular main controller ne susudua module ahorow
Nea ɛfata yiye ma
Telecom nsɛmma nhoma ahorow
-48 VDC nkyekyɛmu
DC adesoa a wɔde hwɛ nneɛma so
Baa dwumadibea-gyinabea DC ahoɔden susuw

DFPM211 Multi-Channel AC Ahoɔden Mita
DFPM211 yɛ modular AC mita nhyehyɛe a ɛyɛ ketewa a wɔde di dwuma ma telecom ahoɔden ho nhyehyɛe, data mmeae ne AC dwumadie afoforo a ɛwɔ amansin pii mu.
Nsɛm atitiriw a wɔakyerɛkyerɛ mu
Ɛboa circuits a ɛkɔ soro kodu 45 a ɛwɔ phase baako
Ɛboa amansin a ɛwɔ fase abiɛsa a ɛkɔ soro kodu 15
Voltage ne mprempren pɛpɛɛpɛyɛ: Class 0.5S
Ahoɔden a ɛyɛ pɛpɛɛpɛ: Adesua 1.0
RS485 nkitahodi
Modbus RTU nhyehyeɛ
Mfaso a ɛwɔ instɔlehyɛn a wɔakyerɛw ato hɔ
Ɛkora 50% a wɔde besisi hɔ
Ɛkora nnɔnhwereɛ a wɔde hyehyɛ so 50%
Ɛkora 50% system debugging bere so
Best t fata ma
AC a wɔkyekyɛ no a ɛyɛ medium-density
Telecom adwumayɛbea ahorow
Aguadi mu ahoɔden a wɔde di dwuma
Data-center aboafoɔ nkyekyɛmu

DFPM206 Multi-Channel AC Ahoɔden Mita
Wɔayɛ DFPM206 ama data centers ne server rooms a ɛhia high-density endpoint ahoɔden data a wɔboaboa ano ne bere ankasa mu tumi-kyekyɛ so hwɛ.
Nsɛm atitiriw a wɔakyerɛkyerɛ mu
Ntrɛwmu biako anaa abien a ɛba
Maximum 144-channel baa dwumadibea a ɛba no sohwɛ
24- anaa 48-channel baa dwumadibea nhwehwɛmu module ahorow
Baa dwumadibea CT a wobetumi apaw: 50 A anaa 100 A
Clamp-on anaa split-core CT a wobɛpaw
Nhwɛsoɔ a ɛfa neutral ne leakage-current a wɔpaw
Voltage ne mprempren harmonic nhwehwɛmu kosi 63rd order
Digital inputs awotwe ne digital outputs mmienu
RJ45 baako ne RS485 nkitahodiɛ ntam nkitahodiɛ mmienu
Modbus RTU ne Modbus TCP
HMI a ɛwɔ touchscreen a wopɛ
Nsɛm a esisii ho kyerɛwtohɔ bɛboro 5,000
Abakɔsɛm mu nsɛm a ɛsisiiɛ ho asɛmmisa ne mfomsoɔ a wɔhwehwɛ
DIN-keteke a wɔde si hɔ
Nsusuwii a ɛyɛ pɛpɛɛpɛ
Voltage ne mprempren: ±0.5% .
Ahoɔden ne ahoɔden: ±1% .
Mpɛn pii no: ±0.02 Hz
Nea ɛfata yiye ma
Data mmeae a wɔde nsɛm gu
Server adan a wɔde ma
High-density baa dwumadibea amansin sohwɛ
Tumi-kyekyɛ panels a ɛho hia
Endpoint ahoɔden a wɔde di dwuma
Ɔkwan Bɛn so na DFPM206 144-Circuit System no Yɛ Adwuma?
Wɔasisi DFPM206 nhyehyɛe bi wɔ ntoatoaso anan a wɔayɛ no biako mu:
1. Baa dwumadibea mprempren transformers
Mprempren transformers susuw ankorankoro outgoing circuits. DFPM206 boa 50 A ne 100 A baa dwumadibea CT akwan horow wɔ clamp-on anaa split-core nhyehyɛe ahorow mu.
2. Baa dwumadibea ahorow a wɔhwɛ so module ahorow
DFPM206 baa dwumadibea akuw no hwɛ amansin 24 anaa 48 a ɛwɔ fase biako so. Wobetumi aka module ahorow pii abom de ayɛ nhyehyɛe no kɛse akodu baa dwumadibea akwan 144 a ɛboro so.
3. Ɔhwɛfo titiriw
DFPM206 main controller no hwɛ lines baako anaa mmienu a ɛba, hyehyɛ branch data na ɛma nkitahodie ne upstream monitoring platform.
4. Mfinimfini hwɛbea a wɔde hwɛ nneɛma so
Controller no nam Modbus TCP anaa Modbus RTU so di nkitaho kɔ tumi a wɔhwɛ so, data-center infrastructure management, ɔdan sohwɛ anaa ahoɔden sohwɛ platform so.
Nea afi mu aba ne nhyehyɛe biako a wɔayɛ no biako a wɔde hwɛ nneɛma so fi mprempren sensor no so kosi management platform no so.

Data Centers a Wɔde Di Dwuma
Hwɛ baa dwumadibea amansin a ɛwɔ density kɛse, aduan a ɛba ne server-room ahoɔden kyekyɛ so. DFPM206 boa adwumayɛfoɔ ma wɔde adesoa toto ho, hunu amansin a ɛnyɛ ne kwan so na wɔde baa dwumadibea-gyinabea data ne centralized monitoring platform bom.
Telecom Nsɛmma Nhoma
Fa DFPM201 di dwuma ma -48 VDC adesoa anaa DFPM211 ma AC kyekyɛ. Nhwɛsoɔ mmienu no nyinaa boa centralized multi-circuit susudua wɔ ahunmu-constrained telecom mmeaeɛ.
Nnwumayɛbea Ahorow
Centralize adesoa ne ahoɔden sohwɛ wɔ multi-circuit tumi panels. Fa baa dwumadibea susudua di dwuma de boa tumi nhyehyɛe, nsiesie ne ahoɔden nhwehwɛmu.
Adan a Wɔde Di Dwuma
Hwɛ wɔn a wɔagye adan, fam, nnwinnade akuw anaa mmeae a wɔyɛ adwuma a womfa mita a edi mũ a ɛyɛ soronko nsi hɔ mma ɔmansin biara a wɔhwɛ so.
Tumi Nhyehyɛe a Ɛho Hia
Track incoming ne outgoing circuits wɔ systems a uptime, alarm visibility ne centralized data access yɛ adwumayɛ mu nneɛma a ɛho hia.
FAQ
Q1: Nsonsonoe bɛn na ɛda multi-loop energy meter ne amanne kwan so mita ntam?
A: Mpɛn pii no, ahoɔden mita a wɔtaa de di dwuma no susuw ɔmansin biako. Multi-loop ahoɔden mita de controller biako ne modular measurement units di dwuma de hwɛ incoming ne branch circuits pii wɔ nhyehyɛe biako a wɔayɛ no biako mu.
Q2: So DFUN nhyehyɛe biako betumi ahwɛ amansin 144 so?
Q3: So '144 circuits, nhyehyɛe biako' kyerɛ honam fam mita biako?
Q4: DFUN model bɛn na ɛboa DC circuits?
Q5: DFUN model bɛn na ɛboa AC circuits 45?
Q6: Nkitahodi nhyehyɛe bɛn na DFPM206 boa?
Q7: So DFPM206 betumi ahwehwɛ harmonics mu?
Q8: So DFPM206 fata ma data centers?
Q9: Mɛyɛ dɛn anya DFUN multi-loop meter proposal?
Blog ahorow a ɛfa ho
-
Mfinimfini ahoɔden a ɛko tia yɛ VRLA batere akwahosan ho nsɛnkyerɛnne a edi kan a wotumi de ho to so sen biara no mu biako, nanso amansan nɔma biako biara nni hɔ a ɛkyerɛ wo bere a ɛsɛ sɛ wosesa batere — akenkan no kyerɛ biribi a ɛne nkwammoaa no ankasa mfiase nhyia nkutoo. Saa asɛm yi bubu 50%-above-baseline replacement mmara, 20–30% cell-to-cell deviation check a wɔde hu unit a ɛka akyi, ne nea enti a mpofirim ahuru wɔ resistance mu ho hia sen absolute value a ɛkorɔn. Ɛsan nso ka nea enti a resistance nkutoo nnɔɔso — pairing no ne float voltage checks, capacity discharge testing, ne visual inspection — ne sɛnea DFUN’s integrated battery monitoring ne capacity testing platform no ma threshold tracking yɛ adwuma wɔ string mũ no nyinaa so.Nsɛm a Wɔayɛ ho Nhwehwɛmu -
Data center yɛ ade titiriw a ɛwɔ adwuma biara mu wɔ nnɛ wiase a data na ɛkɔ so no mu. Nkɔanim kɛse aba wɔ data a wɔkora so ne ne sohwɛ ahiade mu wɔ mfe du a atwam no mu, na ɛde nkɔanim aba wɔ data mmeae ahorow no kɛse, ne kɛse, ne nea ɛyɛ den mu. Wɔ saa tebea yi ase no, akyirikyiri hwɛ solutBotae Asɛmti -
Wɔ mmeae a ɛho hia wɔ asɛmpatrɛw adwuma te sɛ wimhyɛn gyinabea, data mmeae, ne sukuupɔn akɛse mu no, ahoɔden a wɔde sie ho ahotoso ho hia. Batere mpempem pii a wɔbɛhwɛ so wɔ UPS nhyehyɛe ahorow mu no abɛyɛ nea ɛyɛ den kɛse, na akwan a wɔfa so siesie no atetesɛm no nnɔɔso bio.Nsɛm a Wɔayɛ ho Nhwehwɛmu
Nya DFUN Multi-Loop Mita Ho Nsusuwii
Fa wo circuit count, single-line diagram ne nkitahodi ahwehwɛde ahorow mena yɛn. Yɛn kuw no bɛkamfo DFUN controller a ɛfata, susudua module ne mprempren sensor ahorow akyerɛ.
Nsɛm a wɔka kyerɛ:+86- 15919182362
E-mail: info@dfuntech.com