A ziaktu: Site Editor Thuchhuah Hun: 2024-07-30 A chhuahna hmun: Hmun
Substation hrang hrang atana inbiakpawhna power supply .
DFUN DFCCT48 Battery Remote Online-a awm theihna Testing System
Substation, base station, leh transportation-a 48V power system atan a tha.
Hnathawh tam tak chu remote capacity testing, energy hmanga discharging, fing taka charging, battery monitoring, leh battery activation te a ni.
Bus voltage inthlauhna balance turin pre-charge function a awm a, hei hian battery-a charging-a nghawng sang tak a neih tur a veng thei a ni.
Primary leh secondary side inkarah electrical isolation a awm a, anti-interference theihna chak tak leh operation nghet tak a pe thei a ni.
Constant current discharge with boosted voltage, physical circuit isolation, leh real load discharge hian heat generation hniam leh safety sang tak a siam a ni.
Dispersed sites hian maintenance atan hun leh operational cost a thlen thin.
Battery enkawlna tha tak leh alarm hnathawh a awm loh.
Routine inspection-ah chuan battery voltage leh information dang mimal tehna a ngai a, chu chuan hna a thawk sang hle.
Maintenance personnel te chuan battery chhiatna an hmu nghal thei lo a, hei hian himna atana hlauhawm a thlen thei a ni.
Manual inspection hi hun khawhralna leh hnathawk tam tak, tihsual nei awlsam tak, record leh vawnhim harsa tak a ni.
Remote online capacity testing: Battery te chu real-time monitoring leh online management neiin digital monitoring fing tak a siam thei. Battery charging leh discharging, maintenance planning, leh schedule ang zela automated discharge te remote control theihna a siam. Maintenance personnel te chuan inspection an nei thei a, an awmna hmuna awm lovin charging/discharging an enkawl thei a, efficiency an ti tha thei a, workload an ti tlem thei bawk.
Energy save leh environment friendly: DC/DC real load discharge chu power hloh 5% hnuai lam a ni a, hei hian carbon emission a tihtlem phah a ni. Capacity test vawi hnih atan site khatah electric kWh 100 a humhim thei. International Energy Agency chhinchhiah danin, electric kWh khat siam chhuah chuan CO2 kilogram 0.78 vel a chhuah a ni. Hei hian kum tin site khatah CO2 emission kilogram 78 a tihtlem phah a ni (2V 1000AH battery atanga chhut).
Intelligent Charging: Safety a tichak a, three-stage intelligent charging a nei a, undercharging leh overcharging a veng thei bawk. Real load discharge hian himna leh energy efficiency a tichiang a ni. Battery balancing function hian battery pack chhunga battery hrang hrangte voltage danglamna phenomenon a huam a, battery service life a ti rei bawk. Charge/discharge cycle lai hian system hian battery integration a vawng reng a, Mains power outage lai pawhin power supply tihtawp loh a awm theih nan leh discharge risk tihziaawmna a ni.
Internal resistance leh impedance te hi eng nge an danglamna?
Wired vs. Wireless Battery Monitoring System eng ber nge tha zawk
DFUN Tech: Battery hman dan leh enkawlna hun fing tak hmahruai
Distributed vs. centralized battery monitoring system: a tha, a tha, leh a hmanna tur tha ber berte
Battery monitoring system leh renewable energy sources te inzawmkhawmna
UPS application atana battery monitoring system hman dan tur tha ber .