Takeaways pawimawh tak tak:
  • Oil leh gas environment hian UPS battery a tichhe chak hle
  • Internal resistance sang chho zel hi hlawhchhamna hriattirna hmasa ber pakhat a ni
  • Manual inspection ringawt pawh hian battery chak lo tak takte chu rintlak takin a hriat theih loh
  • Battery enkawl chhunzawm zel hian hnathawhna himna leh rintlakna a tisang a ni
  • Predictive maintenance hian downtime leh maintenance senso a ti tlem a ni

Oil refinery, tuipui kama platform, petrochemical plant, leh industrial facility-ah te chuan emergency shutdown system, communication infrastructure, kangmei laka invenna, leh UPS hnathawhna enkawlna atan backup battery system hi a pawimawh hle.

Mahse, boruak khirh tak tak, boruak lum lutuk, gas chhe thei, boruak lum leh vibration te hian battery chhiatna nasa takin a ti chak a ni. Industrial infrastructure a lo lian chhoh zel avangin battery rintlakna tur atan chuan hmanlai kut hmanga enfiah dan hmanlai chu a tawk tawh lo.

200K+ a ni
BASF chemical facility-a battery enfiah a ni
65% a ni.
Industrial outage vangin UPS battery a chhiat vang a ni
80% a ni.
Battery chhiatna chu proactive monitoring hmanga ven theih a ni

Oil & Gas Environment-a Battery Harsatna awm fo

Environment dinhmun khirh tak tak

Oil leh gas facility-te hian battery-te chu industrial infrastructure-a hnathawhna hmun nasa ber ṭhenkhatah a hruai lut a:

  • Ambient temperature sang tak a ni
  • Corrosive gas leh salt air te a awm
  • Humidity sang tak a awm
  • Mechanical hmanga tiharh a ni
  • Hmun hla tak leh kal harsa tak tak te

Heng thilte hian corrosion, internal degradation, electrolyte loss, leh thermal stress te a ti chak a — battery service life nasa takin a ti tawi a ni.

Offshore UPS battery room enkawl dan tur ruahmanna siam a ni
Remote offshore battery room – humidity sang, vibration, leh access tlem

Battery chak lo hriat harsat

String chhunga battery pakhat a chhiat chuan UPS system pumpui performance a tichhe thei a ni. Hun bi neia kut hmanga enfiah a nih pawhin failure indicator tam tak chu hmuh theih lohvin a awm reng a ni.

Downtime leh himna atana hlauhawm

  • Emergency shutdown a nih loh chuan
  • Kangmei laka invenna system hloh
  • Communication system tihbuai a ni
  • Production downtime a awm bawk
  • Environment lama thil thlengte
  • Hriselna atana hlauhawm tak tak

UPS Battery a chhiat thu hriattirna hmasa ber

Chhungril lama dodalna sang chho zel

Battery chhiatna leh discharge capability tlahniam tih hriattirna hmasa ber zinga mi.

Temperature pangngai lo tak a ni

Localized overheating hian internal short circuit emaw thermal runaway risk emaw a kawk thei.

Voltage inthlauhna (Imbalance) a awm

Battery inkara voltage deviation hian charger issue emaw cell degradation emaw a hriattir fo thin.

Terminal-a Corrosion a awm

Corroded terminal hian resistance a ti sang a, current delivery performance a ti tlem bawk.

Battery terminal a chhe tawh
Battery terminal-a corrosion – a resistance tihpun
UPS battery thermal imaging hmanga enfiah a ni
Thermal imaging hian a hlawhchham hmain hot spot a hmuchhuak thin

Engvangin nge Manual Battery Inspection hi a tawk tawh lo

Industrial facility-a battery enkawl dan pangngai chu a tlangpuiin scheduled manual inspection leh periodic testing-ah a innghat a ni. Heng hmanrua te hian thil hmuh theihte a hriat theih laiin, tunlai oil leh gas environment-ah chuan battery system lian zawk, sem darh zau zawk leh a hma aia pawimawh zawkna hmunah chuan a tawk lo zual zel a ni.

Quarter tin enfiahnaah battery chu a hrisel angin a lang thei a, maintenance interval inkarah chuan internal degradation a lo awm chhunzawm zel thung.

Manual testing-a key limitation:
A hun hunah enfiahna hian a hun takah snapshot chauh a pe a ni. Maintenance visit inkara battery behavior inthlak danglamna chu real-time-ah an hmu thei lo.
  • Manual inspection hi hnathawk tam tak a ngai a, hun a duh rei hle bawk
  • Tuipui kama hmun hla tak tak leh hmun hlauhawm tak takah chuan enfiah tamna a ti tlem a ni
  • String lian tak tak chhunga battery chak lo chu kut hmanga hriat a harsa hle
  • Inspection ruahman sa inkarah thermal runaway risk a lo awm thei a ni
  • Mihring tihsual leh report inmil lo hian maintenance rintlakna a ti tlem a ni

Battery Monitoring Systems-in rintlakna a tihchangtlun dan

Tunlai battery monitoring system hian battery pakhat zel chhunga battery voltage, temperature, current leh internal resistance te chu real-time-in a enfiah chhunzawm zel a ni.

  • Voltage leh temperature enfiah chhunzawm zel
  • Internal resistance trend thlirletna a ni
  • Alarm hriattirna automatic a awm
  • Hmun hla tak atanga centralized monitoring neih a ni
  • SOC leh SOH te thlirletna a ni
  • Charge leh discharge report a ni
Battery enfiahna dashboard a ni
Centralized real-time monitoring dashboard a awm bawk
Industry Standards:
IEEE 1188 battery enkawl dan tur rawtna · IEEE 450 stationary battery enkawl dan · IEC battery himna kaihhruaina · NERC critical power reliability standards

Industrial Battery enfiahna project finfiah tawhte

Saudi Aramco a ni

3,000+ a ni

Industrial UPS system 14-ah battery enfiah a ni.

BASF Germany ram a ni

200,000+ a ni

Battery room 3,000-ah battery enfiah a ni.

PTT Thailand ah an awm a

Offshore-ah a awm

Tuipui boruak a battery monitoring hman dan.

Pertamina Indonesia ramah a awm

Industrial lam a ni

Refinery infrastructure hrang hranga UPS battery enfiahna.

Oil refinery-a battery system hman dan tur
Oil refinery lian takah battery monitoring dah a ni

Oil & Gas atana Industrial Battery enkawl dan tur ruahmanna siam a ni

Battery monitoring solution rintlak zawk i zawng em?

DFUN hian battery monitoring system fing tak tak a pe a, chu chu:

  • Oil refinery leh petrochemical plant te pawh a awm bawk
  • Offshore platform leh tuipui boruak te
  • Industrial UPS leh emergency shutdown system te a awm bawk
  • Battery room lian tak tak sem chhuah a ni
  • Remote centralized monitoring leh predictive maintenance hmanga enkawl a ni
BMS Solution chhui rawh →

Related Resources rawtna siamte

Zawhna Zawh fo thin

Engvangin nge oil leh gas facility-ah battery monitoring hi a pawimawh?

Battery hmanga siam system hian emergency shutdown, kangmei laka invenna leh inbiakpawhna te a pui a ni. Monitoring chhunzawm zel hian beisei loh taka chhiatna a thlen loh nan a pui a, operational safety a ti tha bawk.

Battery monitoring system hian thermal runaway a hmu thei em?

Awle. Tunlai system te hian thermal runaway a lo awm hmain temperature leh internal resistance te chu an enfiah chhunzawm zel a, chu chuan thil tih dan pangngai lo a hmuchhuak thin.

Offshore environment-a UPS battery a chhiat chhan chu eng nge ni?

Heat, humidity, vibration leh corrosive salt air te hian degradation a ti chak a, battery service life a ti tawi bawk.

DFUN BMS hian Modbus leh SNMP integration a support em?

Awle. DFUN battery monitoring system hian Modbus, SNMP, MQTT, leh IEC61850 communication protocol te a support a ni.

DFUN hmangin Industrial Battery Reliability tihchangtlun

DFUN hian khawvel puma oil refinery, offshore platform, chemical plant, data centre, leh industrial UPS application hrang hrang tan battery monitoring system fing tak a pe a ni.

Battery Assessment a thlawna neih theih a ni

Kan BMS engineer pakhat chuan darkar 24 chhungin a chhang ang.

(Optional. Technical lama harsatna hmanhmawhthlak tak tak tan chauh)

I privacy kan zah hle. I information chu i dilna chhanna atan chauh hman a ni ang.

Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 ah zawhfiah theih a ni
  +86-756-6123188 ah zawhfiah theih a ni

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni