Availability: | |
---|---|
Quantity: | |
DFPA192-50C2 / DFPA384-50C2
DFUN
-High-Rate Battery Cells (Standard): Meets the requirement for short-term backup power of ≥30 minutes and ≥1500 cycles.
-Auto-Start Function: Enables unmanned operation by automatically restarting after power restoration.
-Triple Automatic Protection: Supports protection at the positive and negative electrodes and the circuit breaker, ensuring battery reliability.
-PACK-level fire suppression (Standard) and cabinet-level fire suppression (Optional) for precise and rapid-fire suppression.
-Cycle Life of LiFePO4 Cells: ≥2500 cycles at 1C charge/discharge rate, ≥1500 cycles at 4C discharge/0.5C charge rate.
-Integrated Smart-Li Battery Monitoring Cloud Platform: Ensures safe and efficient operation and maintenance, reducing daily operational costs.
-Modular Design: Simplifies installation with quick setup; maximum of 6 cabinets in parallel, offering flexible backup time options.
Lithium-ion Battery System Cabinet | Li-ion Battery System Model | DFPA192-50C2 | DFPA384-50C2 |
Capacity for UPS system | 6-20KVA | 10-40KVA | |
Rated Output Voltage (V) | 192V | 384V | |
Battery Module Model | 96V50Ah-2C | ||
Number of Battery Modules (pcs) | 2pcs | 4pcs | |
Battery Cluster Capacity (Ah) | 50Ah | ||
Battery Cluster Power (kWh) | 9.6kWh | 19.2kWh | |
Max. Constant Discharge Current of Battery Pack | 100A | ||
Max. Discharge Power of | 19kW | 38kW | |
Equalizing Charge Voltage (V) | 207V | 414V | |
Floating Charge Voltage (V) | 204V | 408V | |
Cut-off Discharge Voltage (V) | 168V | 336V | |
Communication Interface | CAN/RS485/Dry Contact | ||
Protection | Overcharge, Over-discharge, Over-temperature, Over-current, Short circuit, etc. | ||
Dimension (LxWxH) | 600-1000-1000mm | 600-1000-1200mm | |
Weight | Module Weight XN + Cabinet Weight 120 | Module Weight XN + Cabinet Weight 150 | |
Working Temperature | 0-40℃ (Recommended 20-25℃) |
-High-Rate Battery Cells (Standard): Meets the requirement for short-term backup power of ≥30 minutes and ≥1500 cycles.
-Auto-Start Function: Enables unmanned operation by automatically restarting after power restoration.
-Triple Automatic Protection: Supports protection at the positive and negative electrodes and the circuit breaker, ensuring battery reliability.
-PACK-level fire suppression (Standard) and cabinet-level fire suppression (Optional) for precise and rapid-fire suppression.
-Cycle Life of LiFePO4 Cells: ≥2500 cycles at 1C charge/discharge rate, ≥1500 cycles at 4C discharge/0.5C charge rate.
-Integrated Smart-Li Battery Monitoring Cloud Platform: Ensures safe and efficient operation and maintenance, reducing daily operational costs.
-Modular Design: Simplifies installation with quick setup; maximum of 6 cabinets in parallel, offering flexible backup time options.
Lithium-ion Battery System Cabinet | Li-ion Battery System Model | DFPA192-50C2 | DFPA384-50C2 |
Capacity for UPS system | 6-20KVA | 10-40KVA | |
Rated Output Voltage (V) | 192V | 384V | |
Battery Module Model | 96V50Ah-2C | ||
Number of Battery Modules (pcs) | 2pcs | 4pcs | |
Battery Cluster Capacity (Ah) | 50Ah | ||
Battery Cluster Power (kWh) | 9.6kWh | 19.2kWh | |
Max. Constant Discharge Current of Battery Pack | 100A | ||
Max. Discharge Power of | 19kW | 38kW | |
Equalizing Charge Voltage (V) | 207V | 414V | |
Floating Charge Voltage (V) | 204V | 408V | |
Cut-off Discharge Voltage (V) | 168V | 336V | |
Communication Interface | CAN/RS485/Dry Contact | ||
Protection | Overcharge, Over-discharge, Over-temperature, Over-current, Short circuit, etc. | ||
Dimension (LxWxH) | 600-1000-1000mm | 600-1000-1200mm | |
Weight | Module Weight XN + Cabinet Weight 120 | Module Weight XN + Cabinet Weight 150 | |
Working Temperature | 0-40℃ (Recommended 20-25℃) |