Dilancogo jɛlen: 48V DC sitɛmu min bɛ rectifier module, monitoring unit, kuran tilali yɔrɔ, batiri, ani bɛɛ lajɛlen don kelen kɔnɔ
Batiri litiyamu hakilitigi : Batiri litiyamu hakilitigi bɛ batiri kura ni batiri kɔrɔw ni batiri plɔmu-litiyɔmu ɲagaminen dɛmɛ, wa a bɛ ni hakilitigiya fanga bonya baara ye walasa ka 5G yɔrɔjan kuran magow ɲɛ
Setigiya caman dilancogo: fo ka se 600A(36KW) ma
Dɛmɛ min bɛ se ka kɛ kosɛbɛ: Dɛmɛ min bɛ se kulu 10 ma, 48V100AH walima 48V165AH batiri hakilitigiw litiyamu
Kuran caman doncogo dɛmɛ: A bɛ kuran, dizili ani tile dɛmɛ.
Sisitɛmu kabini caman dɛmɛ ɲɔgɔn fɛ: dɔ fara bɔli fanga kan
Dɛmɛ don fanga maracogo caman na: peak shaving mode, peak regulation mode, wdfl.
Yɔrɔ mara walasa ka kumaɲɔgɔnya minɛnw sigi
Furakɛcogo suguya |
Fɛnɲɛnɛma 1 (Kɛnɛma) . |
Fɛnɲɛnɛma 2 (So kɔnɔ) . |
|
Fɛn dilannen suguya |
DFCA48-O-XXX-XXX-X ye baara kɛ ni a ye |
DFCA48-I-XXX-XXX-X ye baara kɛ ni a ye |
|
Sisitɛmu |
A bonya (W × D × H) . |
700mm×800mm×2200mm ye |
600-800-2000mm ye |
Girinya |
< kilo 256 (ni rectifier modules, batiri, minɛn wɛrɛw tɛ yen minnu bɛ se ka kɛ ) . |
< 200 kg (ni rectifier modules, batiri, minɛn wɛrɛw bɛ se ka kɛ) |
|
Installation (dadoncogo) cogoya |
Dugukolo sigili (Kɛnɛma) . |
So kɔnɔ |
|
Kabɛli kɛcogo |
Ka bɔ duguma |
Ka bɔ duguma walima sanfɛ |
|
Ladonni cogoya |
ka bɔ ɲɛfɛ . |
ka bɔ ɲɛfɛ ni kɔfɛ . |
|
Kabinet Materiel |
SGCC galvanisé sɛbɛn ni sɔgɔli barikama . |
SPCC ka bon kosɛbɛ nɛnɛ wulilen nɛgɛ plati |
|
Kabini kulɛri |
Gris clair: RAL 7035. Bamako, Mali |
Gris clair:RAL9007 |
|
Baro min bɛ dugukolo kan . |
7×M6,1×M8 ye |
||
EMC ye |
EN300386 Kalanso A |
||
Lakanali Nivo |
IP55 . |
IP20 ye |
|
Batiri |
Kɔnɔna Rack & Yɔrɔ |
3U, 19-inch rack (ka kɛɲɛ ni a labɛncogo yɛrɛ ye) . |
|
Batiri suguya . |
Max. 10pcs DFPA48100-S/DFPA48165-S. Bamako, Mali |
||
Cooling Mode (Nɛnɛ kɛcogo). |
DC Air Conditioner (Kɛnɛyajibɔlan) . |
DC48V 1000W ye |
AYI |
P ower tila-tila yɔrɔ |
AC Donna |
220/384Vac fasa saba naani-filɛri, min bɛ bɛn fasa kelen fasa saba ma: 200-240 Vac/346-415 Vac fasa kelen: 200-240Vac, dɛmɛ don dizili jɛnɛrato dondaw la |
|
ATS suguya |
ATS-63A1/ATS-63A2/ATS-125C1 (a bɛ se ka kɛ, AC donna fila dɔrɔn de kama) |
||
PV Donna |
Donna tension: 102V (range 70-150V) , Donna seko 63A/2P*4 |
||
DC Bɔli |
Voltage:Normal Mode: 42VDC-58VDC, Boost Module: 53.5VDC ka dɛmɛ don 57VDC constant (a ka kan ka sigi ni Smart Lithium Battery ye) |
||
Sisan Max.36kW(600A) ye. |
|||
Batiri bolofara |
MCB:125A×10 ye |
||
LLVD ka tɔnbolofara |
2×125AMCB,3×63AMCB (LLVD1) Bamako, Mali. |
||
BLVD ka tɔnbolofara |
2×32AMCB,2×40AMCB,4×63AMCB ,4×63AMCB ,2×125AMCB |
||
SP D. ye |
AC donna::40kA (8/20μs) |
||
DC bɔli: 20 kA/max=40KA,8/20 μ |
|||
Rectifier (Kɔrɔsilikɛla). |
Donni/Bɔli |
Donna 85-300VAC;Bɔli 42-58VDC;Fanga 3000W, a ka ca ni 12 ye |
|
PV (PV) ye Module (Module) ye |
Donni/Bɔli |
Donna tension: DC70-150V Bɔli: 3000W( 0-62.5A@-42Vdcto-58Vdc): baarakɛcogo ɲuman ≥ 0,96 (a bɛ se ka kɛ) |
|
Kɔlɔsili |
Interface (interface) Labɛncogo |
DI donna: DI * 6, DO bɔli: DO * 6, Kumaɲɔgɔnya siratigɛ: RS485 * 1, LAN * 1 |
|
Sigida |
Baarakɛcogo funteni |
0oC fo +45oC + tile yeelen (dɛmɛ -20oC ni a labɛnna ka kɔn funteni kɛsu ɲɛ)) |
|
A maracogo funteni |
–40°C ~ +70°C ye |
–20°C ~ +60°C ye |
|
Baarakɛcogo min bɛ kɛ relative ye ni Humidité |
5% fo 95% (a tɛ kɛ ni fɛnɲɛnamafagalan ye) . |
||
Kɔrɔya |