dfun indonesia battery enkawl dan tur ruahmanna siam a ni

Project chungchang tlangpui

Indonesian data center project hian data dahkhawmna leh tihfelna tur hmun tha tak, nghet tak leh him tak siam a tum a ni. Power supply tihtawp loh nan he project hian 12V VRLA Hoppecke battery unit 9,454 a hmang a ni. DFUN-a Battery Management System (BMS), a hnathawh dan danglam tak leh rintlakna avanga hriat hlawh tak hi data center-a backup power system-a thil pawimawh tak a ni.


BMS System hlutna leh pawimawhna


Real-Time Monitoring & Alerts: Power Supply rintlak taka enkawl

DFUN BMS hian battery 9,454 zawng zawng chu a hun takah a enfiah vek a, voltage, current, internal resistance, leh temperature te ang chi parameter pawimawh tak takte chu dik takin a la thei a ni. Real-time data thlirletna hmang hian system hian operator-te chu anomalies awmte chu a hriattir nghal a, hei hian rang taka siamthatna tur a siam thei a ni. He theihna hian backup power system chu 'clairvoyant vision' leh 'acute hearing' hmangin a thuam a, chu chuan condition zawng zawngah power nghet leh rintlak a siamsak a, chu chuan outage avanga operational loss awm chu a veng thei a ni.

Optimized Charging/Discharging: Battery dam rei theihna tur

BMS hian real-time battery status a zirin charging strategy chu fing takin a siamrem a, charging/discharging process a ti tha hle. Overcharging emaw undercharging emaw ang chi risk a ti bo a, battery lifespan 30% a ti rei a, charging/discharging efficiency 15% a ti sang bawk . He data center tan hian kum khata battery thlak leh enkawlna senso tihtlem atanga sum khawlkhawm chu USD 28,500 vel a ni.

Automated Management: Hnathawh thatna tihpun

Traditional battery management hian kut hmanga enfiah fo a ngai a, mahse DFUN BMS hian automated oversight a siam thei a ni. Centralized platform hmang hian operator-te chuan battery hriselna chu hla tak aṭangin an enfiah a, equalization charging leh fault diagnosis ang chi routine task-te chu automate-in an ti thei a ni. Implementation hnuah, manual inspection chu 50% in a tlahniam a, nitin maintenance time pawh 40% in a tlahniam a , hei hian data center kalpui dan fing zawk, efficient zawk a thlen a ni.

Data-Driven Decision Support: Sumdawnna tihhmasawn chakna

BMS hian strategic decisions thlawp turin historical data a khawlkhawm a, a zirchiang thin. Entirnan, battery thlak hun tur chu degradation trend hmanga hrilhfiah emaw, operational efficiency tihsan nan power hman dan tur siam that emaw. Data-driven insights hian data center chu sumdawnna mamawh angin dynamically in a insiamrem thei a, service tha zawk a pe thei bawk.


Battery-Monitoring-System-Case-Study neih a ni


PBMS9000 + PBAT51 Solution: Efficiency leh Safety inzawmkhawmna

He project hian DFUN’s PBMS9000 + PBAT51 solution a hmang a ni.

  • PBMS9000 hian centralized management hmasawn tak leh communication protocol tha tak tak hmangin battery array lian tak takte chu hla tak atangin a enfiah thei a ni. A intelligent load-balancing feature hian battery hriselna leh load condition a zirin charging/discharging current a allocate a, localized overcharging/discharging a veng a, system rintlakna chu 40% in a tisang bawk..

  • PBAT51 , battery sensor performance sang tak hian voltage, internal resistance leh temperature te chiang takin a teh thei a ni. A anti-interference theihna chak tak hian electromagnetic environment complex takah pawh a thawk nghet thei a ni.

He solution hi an inzawmkhawm chuan failure rates 35% in a tihhniam bakah battery tinte chu a tha thei ang bera thawk turin a enkawl a, data center stable performance atan lungphum nghet tak a siam a ni.


battery-a enkawl dan-system-51


Tawpna

DFUN-a BMS hian Indonesia data center-ah transformative value a pe a, power rintlakna, operational efficiency, leh thutlukna siam theihna a tipung a ni. DFUN BMS thlan hian data hmanga infrastructure hmalam hun humhalh tihna a ni.


Kan Inzawmkhawm

Product Category hrang hrang a awm

Quick Links te pawh a awm

Min rawn biak theih reng e

 tih a ni  info@dfuntech.com
   +86- 15919182362 a awm a.
  +86-756-6123188 ah zawhfiah theih a ni
 tih a ni  +86- 15919182362 a ni.

A thuneihna hi 2023 DFUN (ZHUHAI) CO., LTD. Thuneihna zawng zawng humhalh a ni. Thuruk humhalh dan tur | Sitemap a ni